Survey Execution

Selecting, Collecting and Preserving Plant Material

Microsite Summary

Plant-material sampling is the point at which the statistical survey is converted into a biological sample for genotyping.

A good sampling protocol must ensure that the physical sample:

  • represents the biological unit defined in the survey design;
  • is linked unambiguously to the correct household, planting, field, inventory or aggregation source;
  • preserves individual-plant identity where required;
  • captures population-level composition where that is the objective;
  • remains free from avoidable contamination;
  • is dried and preserved adequately;
  • can be traced through laboratory processing and genotyping.


IMAGE experience shows that there is no single best material or sample composition for every crop survey. Leaf, grain and root tissue can all be useful under different circumstances, and single-plant and multiple-plant samples answer different biological questions.

The central principle is:

Collect the material that best represents the biological unit the monitoring question is intended to measure, and preserve its identity and quality from the moment it is sampled. 

1. Introduction and Purpose

This guidance supports teams developing field procedures for selecting, collecting and preserving plant material for genotyped crop surveys.

It addresses:

  • deciding what physical material to collect;
  • selecting plants within a planting;
  • single-plant and multiple-plant sampling;
  • homogeneous and heterogeneous target materials;
  • leaf, grain and root sampling;
  • sampling standing crops and stored material;
  • aggregation-point sampling;
  • avoiding contamination;
  • drying and preservation;
  • wet-weather handling;
  • field quality assurance;
  • sample acceptance and rejection;
  • preparing samples for transfer to the laboratory.


The guidance is intended to complement the broader Planning and Designing a Genotyped Crop Survey chapter. The survey design should already have defined:

  • the monitoring question;
  • target population;
  • selected planting, field, inventory or lot;
  • intended level of inference;
  • what the physical sample should represent.


The sampling team should implement that design rather than redefine it in the field.

IMAGE field protocols emphasized three basic requirements:

samples must be labelled so that they can be matched to other records;

samples must be collected in a form that can be dried and preserved appropriately;

where individual plants or a specified number of plants are being sampled, the material must remain traceable to the intended plant or plant population.



2. Intended Users

This guidance is intended for:

  • field coordinators;
  • crop-sampling teams;
  • agricultural survey enumerators;
  • crop scientists;
  • breeders;
  • seed inspectors;
  • laboratory coordinators;
  • GRL teams;
  • supervisors;
  • varietal-monitoring programs;
  • organizations commissioning genotyped surveys.


Laboratory and analytical teams should also contribute to protocol development because field sampling choices affect:

  • DNA extraction;
  • sample processing;
  • genotype quality;
  • interpretation of mixtures;
  • analytical assignment. 
3.Begin With What the Sample Is Intended to Represent

Minimum requirement

Before collecting material, state what each physical sample is intended to represent.

Possible units include:

  • one individual plant;
  • several plants within one planting;
  • the combined population within a planting;
  • crop-cut harvest;
  • stored grain associated with one planting;
  • a seed or planting-material lot;
  • a reference variety;
  • material entering an aggregation point.

The sample should not later be interpreted more broadly than the collection method allows.

For example:

A single plant represents one individual genotype.

It does not automatically represent the dominant genotype of the full planting.

Likewise:

A pooled sample represents the combined genotype of the sampled population.

It does not necessarily mean that every plant contributing to that population has the same genotype.

IMAGE close-out analysis confirmed that single- and multiple-plant samples from the same planting often generate different genetic assignments, particularly where mixtures are present.

4.Select the Sampling Strategy According to the Monitoring Question

A practical decision framework is:

Monitoring objectiveSuitable sampling approach
Identify individual genotypesSingle-plant sampling
Describe genetic material occurring across the landscapeSingle plants distributed across plantings
Assess whether a planting population corresponds substantially to a target materialMultiple-plant pooled sample
Detect mixture within a plantingSeveral single plants, possibly alongside a pooled sample
Characterize a seed or inventory populationPopulation-level sample
Link genotype with crop-cut yieldCrop-cut population sample
Obtain individual-plant genotypes where grain has already been collectedIndividual grain/seed grow-out followed by leaf-tissue sampling
Detect distinct material suggested by visible differencesPhenotype-targeted single plants
Screen efficiently and investigate mixture laterStaged pooled + single-plant approach

There is no universal preferred approach.

5.Single-Plant Sampling

A single-plant sample represents the genotype of one individual plant.

Recommended where the objective is to:

  • identify individual genetic components;
  • investigate genetic diversity within plantings;
  • detect minority genotypes;
  • obtain clean reference genotypes;
  • investigate possible laboratory mixture;
  • sample target materials expected to be genetically homogeneous at individual-plant level.

IMAGE close-out analysis showed that single-plant samples generally produce clearer and less ambiguous genotype profiles than multiple-plant samples.

5.1 Important limitation

A clear genotype does not necessarily mean the plant is representative of the planting.

A randomly selected plant could be:

  • the dominant genotype;
  • a minority component of a mixture;
  • an outcrossed individual;
  • a segregating plant.

Single-plant results should therefore be interpreted according to the sampling design.

6.Multiple-Plant Sampling

A multiple-plant sample combines material from several plants into one physical sample.

It can provide an efficient estimate of the population genotype being grown.

Useful where the objective is to:

  • assess whether a planting broadly corresponds to a known target material;
  • characterize the genetic composition of a planting population;
  • characterize a seed or inventory lot;
  • capture mixture without genotyping many individual plants;
  • reduce genotyping cost.

IMAGE field protocols included multi-plant sampling, with the exact number of plants varying across crops and pilots. These numbers should therefore be treated as project-specific configurations rather than universal standards.

6.1 Mixture is not automatically poor sample quality

Where several genetically different plants contribute to a pooled sample, the resulting genotype may show greater ambiguity.

In crops where homozygosity is expected, this can appear as higher levels of heterozygous marker calls.

IMAGE close-out analysis demonstrated this pattern consistently across several crops.

The ambiguity can be biologically informative because it reflects the population sampled.

7.Homogeneous Versus Heterogeneous Target Materials

Minimum design decision

Ask:

Is the target material expected to have a relatively homogeneous individual-plant genotype, or is genetic heterogeneity part of the expected variety?

7.1 Expected homogeneous materials

For materials such as:

  • clonal crops;
  • pure-line inbred varieties;
  • single-cross hybrids based on inbred parents,

single-plant samples can provide useful identity information.

IMAGE applied single-plant sampling to crops including cassava, rice, bean, wheat, tef and cowpea where this logic was appropriate.

7.2 Expected heterogeneous materials

For genetically heterogeneous populations, such as some open-pollinated materials:

  • one plant cannot adequately represent the target variety;
  • population-level sampling is required;
  • observed heterogeneity should not automatically be interpreted as contamination.

The field protocol should therefore reflect the biological structure expected of the crop and target material.

8.Combined Single- and Multiple-Plant Sampling

Where both population identity and individual genetic components are important, both sample types may be collected.

For example:

  • one pooled sample from several plants;
  • one or more individual plants from the same planting.

Where individual-plant sampling cannot be conducted during the original field visit, a population-level grain sample may also provide a source for subsequent individual-plant sampling through grow-out. Individual grains/seeds can be germinated at a research location and leaf tissue collected separately from the resulting plants. Each resulting plant sample should remain traceably linked to the original population sample and Planting ID.

The two sample types should not be treated as interchangeable laboratory replicates.

They answer different questions.

IMAGE Nigeria’s cassava pilot used both single-plant and multiple-plant leaf samples from fields, with each sample assigned a unique barcode linked to the field record.

9.Random and Phenotype-Targeted Single-Plant Sampling

Single plants may be selected in different ways.

9.1 Random single-plant sampling

Use where the objective is to describe:

  • individual genotype occurrence;
  • variation across the landscape;
  • variation among plants without visual preselection.

Plants should be selected without favoring:

  • vigor;
  • plant size;
  • apparent health beyond minimum sample-quality requirements;
  • expected variety identity.

9.2 Phenotype-targeted single-plant sampling

A plant may instead be deliberately selected because it appears different from surrounding plants.

This can be useful when the objective is:

to maximize the probability of detecting genetically different components within a planting.

IMAGE cassava innovation work used this targeted strategy as part of within-field investigation.

Important limitation

Phenotype-targeted plants are purposively selected.

They should not be interpreted as random representatives of the planting.

The sampling strategy should therefore be recorded in the sample metadata.

10.Consider a Staged Sampling Approach

Context-dependent

Where genotyping cost is a constraint, a staged approach may be used.

One example is:

  1. collect a pooled population sample;
  2. retain individually identifiable plant material;
  3. genotype the pooled sample first;
  4. evaluate evidence of mixture or ambiguity;
  5. genotype individual samples only where further resolution is needed.

This can reduce the number of individual samples genotyped.

However, it increases:

  • field preparation;
  • storage requirements;
  • identifier complexity;
  • turnaround time;
  • risk that retained samples become unusable.

It should therefore be planned before fieldwork rather than improvised after pooled results are received.

11.Select the Tissue or Material Type

IMAGE sampling work used several material types.

The most relevant include:

  • leaf tissue;
  • grain;
  • cassava root tissue.

The choice should consider:

  • crop stage;
  • intended biological unit;
  • laboratory requirements;
  • ease of preservation;
  • ability to maintain plant identity;
  • availability during the survey;
  • whether the collected material can support a subsequent grow-out where individual-plant sampling may be required;
  • whether stored material has been mixed.

The laboratory or genotyping provider should confirm that the proposed material is compatible with the extraction method before field deployment. Where individual grains/seeds do not provide sufficient material for the intended genotyping workflow, the protocol should determine in advance whether viable grain will be retained for grow-out and subsequent leaf-tissue collection.

12.Leaf Tissue

Leaf tissue is often advantageous because it can be sampled directly from identified plants.

IMAGE field guidance notes that leaf material can be traced to specific plants and is generally straightforward to prepare for DNA extraction.

12.1 Select suitable tissue

Select tissue that is:

  • healthy;
  • sufficiently developed;
  • green;
  • not heavily damaged;
  • free from obvious disease where possible;
  • not extensively dried or senescent.

Avoid:

  • rotten tissue;
  • severely diseased tissue;
  • scorched leaves;
  • dead or very old leaves;
  • excessively wet or muddy material where a better plant is available.

12.2 Crop-specific tissue specifications

The exact:

  • leaf position;
  • leaf length;
  • amount of tissue;
  • number of leaf pieces

should be defined in a crop-specific field SOP.

IMAGE materials include crop- and activity-specific examples but do not establish one universal tissue quantity.

For example, a later AfricaRice sampling protocol used healthy single plants and three well-expanded leaves at least 5 cm long for that specific GRL activity. This illustrates the type of crop-specific specification that should accompany the generic guidance rather than becoming a universal crop-survey standard.

13.Select Plants Across the Planting

Minimum requirement

Where several plants contribute to the sample, they should represent the defined sampling area rather than being selected only for convenience.

Avoid collecting all material from:

  • the field entrance;
  • one corner;
  • consecutive plants;
  • one row;
  • plants closest to the enumerator.

IMAGE protocols used approaches such as:

  • spatially distributed selection;
  • systematic movement;
  • zig-zag or W-shaped routes;
  • plant intervals.

The specific walking pattern can be adapted to the crop and planting structure.

The underlying principle is:

Spread contributing plants across the intended sampling area.

14.Avoid Field Margins Where Appropriate

Recommended practice

Where feasible, avoid relying heavily on plants located at the outer edge of the planting.

Edge plants may differ because of:

  • neighboring varieties;
  • cross-pollination exposure;
  • management;
  • soil conditions;
  • grazing or damage;
  • different planting density.

However, field shape and smallholder planting structure may make strict edge exclusion impractical.

The field SOP should favor representative spatial coverage rather than prescribe one universal edge distance.

15.Leaf Collection Procedure

A general leaf-sampling workflow is:

  1. Confirm the correct household, field and planting.
  2. Confirm the Sample ID.
  3. Confirm sample type: single plant or multiple plant.
  4. Select the intended plant.
  5. Select suitable healthy tissue.
  6. Use clean cutting equipment.
  7. Collect the specified tissue quantity.
  8. Place the tissue immediately into the correct labelled envelope.
  9. Verify the physical label against the digital record.
  10. Close the envelope.
  11. Place it promptly with active desiccant.
  12. Clean cutting equipment before collecting the next sample.

IMAGE Tanzania protocols used labelled paper envelopes, silica gel, resealable bags and cleaned cutting tools.

16.Prevent Cross-Contamination

Minimum requirement

Tools and contact surfaces should be cleaned between samples where there is a reasonable risk of transferring plant tissue.

IMAGE protocols used approximately 70–75% ethanol for cleaning cutting instruments.

Controls may include:

  • clean scissors or scalpels;
  • ethanol;
  • clean wipes;
  • clean gloves;
  • clean work surfaces;
  • immediate packaging.

Avoid:

  • placing samples directly on soil;
  • placing tissue from several samples on one surface;
  • reusing contaminated wipes;
  • allowing loose plant fragments to remain in the envelope or work area.
17.Grain Sampling

Grain may be collected:

  • from standing mature plants;
  • crop-cut harvests;
  • household storage;
  • mills or other aggregation points.

Each source supports different inference.

IMAGE sampling guidance notes that grain can provide flexible access to material but may require more processing than leaf tissue, particularly where single grains must be germinated to obtain leaf tissue.

Grain can provide flexible access to material but may require additional processing for individual-plant genotyping. A single grain/seed may not provide sufficient material for the intended genotyping workflow; where this occurs, individual grains/seeds can be grown out at a research location and leaf tissue collected from the resulting plants. This provides a pathway from collected grain to individual-plant samples without requiring leaf collection during the original field visit.

18.Grain From Standing Crops

Where grain remains associated with identifiable plants:

  • individual-plant identity can potentially be retained;
  • grain can be collected from several spatially distributed plants;
  • individual and pooled samples can be constructed deliberately.

The protocol should define:

  • number of contributing plants;
  • number of grain units per plant;
  • whether individual plants remain separate;
  • whether pooled material should contain approximately equal contribution from each plant.

Avoid collecting multiple grain units from one plant and treating them as though they represent several plants.

19.Grain From Crop-Cut Harvests

Crop-cut material represents several plants within a defined crop-cut area.

It may be particularly useful where the survey seeks to connect:

  • genotype;
  • field area;
  • yield;
  • household information.

However:

  • individual-plant identity is lost;
  • mixture may occur;
  • the sample should be interpreted as population-level material.

Grow-out option

Where individual-plant genotyping is subsequently required, individual grains/seeds from the crop-cut sample may be grown out at a research location and leaf tissue collected separately from the resulting plants. This may be necessary where individual grains/seeds do not provide sufficient material for the intended genotyping workflow.

A grow-out provides individual plants derived from the sampled crop-cut grain population, but does not restore the identity of the individual plants originally standing within the crop-cut area. Results should therefore be interpreted as individual plants derived from the crop-cut population rather than direct observations of specific plants in the original field.

Each grow-out plant and resulting leaf-tissue sample should receive a unique Sample ID and remain traceably linked to the original crop-cut grain sample and Planting ID.

The crop-cut sample should remain separately identifiable from other harvest material until the genotype subsample is taken.

20.Stored Grain

Context-dependent

Stored grain can be convenient where standing crops are no longer available.

Before sampling, determine:

  • whether grain from different fields has been combined;
  • whether several varieties were mixed;
  • whether the farmer stores varieties separately;
  • whether grain remains attached to ears, pods or panicles;
  • whether the material can be linked confidently to the selected planting.

IMAGE guidance specifically notes that stored grain can become mixed in ways that prevent individual varieties from being distinguished.

If the source cannot be reconstructed, record the sample as:

  • mixed;
  • uncertain;
  • aggregation lot;

rather than assigning a false field or variety identity.

21.Individual-Grain Sampling and Grow-Out

Where individual-grain or individual-plant genotypes are required from collected grain, additional operational steps may be needed.

Depending on the laboratory method:

  • grain may be ground directly;
  • individual seed may need to be germinated;
  • leaf tissue may then be collected from the resulting plant.

Grow-out may be particularly useful where a single grain/seed does not provide sufficient material for the intended genotyping workflow or where leaf tissue is the preferred material for individual-plant genotyping.

Each grain/seed selected for grow-out should remain individually traceable to its source population sample. Each resulting plant and leaf-tissue sample should receive a unique Sample ID linked to the original grain/crop-cut sample and Planting ID.

Grow-out adds:

  • time;
  • research-site or greenhouse capacity;
  • germination and plant-management requirements;
  • labor;
  • additional identifiers and handling steps;
  • opportunities for sample switching or contamination.

The potential information value should therefore justify the additional complexity, and the grow-out and traceability process should be planned before samples are removed from the original grain sample.

22.Cassava Root Sampling

IMAGE Nigeria demonstrated that cassava root tissue can be successfully collected and genotyped.

This is particularly useful where:

  • leaf material is unavailable;
  • cassava roots are encountered at processors or markets;
  • monitoring occurs after harvest.

The Nigeria innovation pilot collected silica-dried cassava root samples from aggregation points across six states and successfully processed them for genotyping.

22.1 General root-sampling principles

The sample should be:

  • from a clearly identified root or lot;
  • free from excessive soil;
  • prepared with clean cutting equipment;
  • sampled from suitable internal tissue;
  • dried rapidly;
  • labelled immediately.

Provider instructions used during IMAGE included rinsing and drying the root, cleaning the scalpel with approximately 70% ethanol before each specimen, cutting a thin section and removing brown external skin.

Exact section size and processing should follow the laboratory/provider SOP in use.

23.Aggregation-Point Sampling

Context-dependent

Aggregation points may include:

  • mills;
  • markets;
  • processors;
  • collection centers;
  • storage facilities.

IMAGE pilots demonstrated that these sites can provide efficient access to many samples.

Nigeria collected cassava root material from markets and processing centers, while Tanzania piloted rice sampling at mills. IMAGE close-out findings supported aggregation-point sampling as a viable monitoring pathway where the inference is defined appropriately.

23.1 Preserve source information where possible

Record:

  • aggregation-point ID;
  • location;
  • date;
  • material type;
  • grower/source identity where available;
  • lot or sack identifier;
  • claimed variety;
  • geographic origin;
  • whether material appears mixed.

23.2 Interpretation limitation

An aggregation-point sample represents material entering that part of the value chain.

It should not automatically be interpreted as representative of:

  • all farmers;
  • national planting area;
  • all material grown in the surrounding region.
24.Label Samples Immediately

Minimum requirement

Every sample should be labelled before or at the moment material is placed into its container.

Do not collect multiple unlabeled samples and label them later.

A good Sample ID system should be:

  • unique;
  • permanent;
  • human-readable;
  • machine-readable where possible.

IMAGE protocols used labelled envelopes and barcode-based linkage between physical samples and field data.

25.Use Dual Labelling Where Practical

Recommended practice

Where paper envelopes are used, include identifier information:

  • outside the envelope;
  • and inside where the protocol supports this.

Tanzania field protocols explicitly used matching internal and external labels.

This provides protection if an external label:

  • detaches;
  • becomes wet;
  • fades;
  • is damaged.
26.Minimum Sample Metadata

Each sample record should include at least:

FieldRequirement
Sample IDMandatory
Planting/source IDMandatory
CropMandatory
Tissue/material typeMandatory
Single/multiple/other sample typeMandatory
Number of contributing plantsRequired for pooled samples
Parent Sample IDRequired for samples derived through grow-out or other subsampling
Sampling strategyRecommended
Collection dateMandatory
CollectorMandatory
Sample conditionMandatory
Batch IDBefore handover
GPSContext-dependent
Photograph referenceContext-dependent
Observed mixtureWhere relevant
Protocol deviationWhere relevant

The metadata should be recorded digitally where possible and linked through the permanent Sample ID.

27.Dry Samples Promptly

Minimum requirement

Samples requiring desiccation should be placed with active drying material as soon as practical after collection.

IMAGE protocols commonly used silica gel in resealable plastic bags containing paper sample envelopes.

Effective drying depends on:

  • adequate desiccant;
  • sufficient contact with air around the envelope;
  • bag integrity;
  • avoiding overcrowding;
  • monitoring desiccant condition;
  • replacing exhausted desiccant.
28.Use Active Silica Gel

Where indicator silica is used, the team should understand the color change indicating moisture absorption.

IMAGE Tanzania protocols used silica that changed from blue to pink as it absorbed moisture and instructed teams to replace it when necessary. Samples were monitored frequently because drying failure could compromise sample integrity.

The exact:

  • silica quantity;
  • number of envelopes per bag;
  • replacement interval

should be defined according to sample type, ambient humidity and field conditions.

A later rice reference-sampling protocol, for example, used approximately 150 g of silica for up to three envelopes under specified conditions. That is an activity-specific example rather than a universal standard.

29.Protect the Drying Container

Minimum requirement

Resealable bags or drying containers should remain:

  • intact;
  • closed;
  • dry;
  • away from direct sun;
  • away from excessive heat.

IMAGE protocols instructed teams to check for holes or damaged bags because moisture entering the container can reduce drying effectiveness.

Where damaged:

  • replace the bag;
  • or double-bag temporarily until material can be transferred safely.
30.Wet-Weather Sampling

Recommended practice

Avoid collecting plant tissue during heavy rain where the survey design and timing permit.

Where wet tissue must be sampled:

  • remove excess surface water gently;
  • use clean material to blot moisture;
  • place tissue promptly in the labelled envelope;
  • start desiccation immediately;
  • monitor the sample more frequently;
  • replace desiccant as needed.

Wet tissue is at higher risk of:

  • fungal growth;
  • rot;
  • poor drying;
  • sample rejection.

The field protocol should include a wet-weather contingency rather than leaving enumerators to improvise.

31.Store Samples in a Cool, Dry Environment

Until transfer to the laboratory, samples should be stored:

  • out of direct sunlight;
  • away from rain and humidity;
  • away from excessive heat;
  • protected from rodents and insects;
  • organized by batch.

IMAGE Tanzania protocols recommended a cool, dry room or space with relatively stable temperature.

Avoid prolonged sample storage:

  • inside hot vehicles;
  • in wet bags;
  • exposed outdoors;
  • in unventilated humid rooms.
32.Transport Samples Frequently

Recommended practice

Do not retain field samples longer than necessary once they can be moved safely to the receiving laboratory.

Transport frequency should consider:

  • preservation system;
  • field location;
  • crop material;
  • laboratory capacity;
  • transport cost.

IMAGE Tanzania protocols used regular scheduled transfer to TOSCI, supported by submission reports and supervisor oversight.

The precise frequency was operationally specific and should not become a universal IMAGE rule.

33.Use a Batch Handover Record

Every transfer should be associated with a Batch ID.

The handover record should include:

  • submitting officer;
  • receiving officer;
  • date;
  • crop;
  • tissue type;
  • Sample ID range or list;
  • number expected;
  • number transferred;
  • sample condition;
  • remarks.

The submitting and receiving persons should reconcile physical and digital sample counts.

Detailed laboratory accession is addressed in the companion Sample Traceability and Laboratory Workflow guidance.

34.Field Quality Assurance

Minimum requirement

Quality checks should occur while sampling is still underway.

34.1 Sampler self-check

Before leaving the planting or source, confirm:

  • correct source;
  • correct crop;
  • correct Sample ID;
  • correct sample type;
  • required number of contributing plants;
  • adequate tissue;
  • physical and digital identifiers agree;
  • sample placed in desiccant;
  • required GPS/photo recorded.

34.2 Supervisor review

Supervisors should review:

  • physical sample count;
  • Sample IDs;
  • preservation condition;
  • desiccant activity;
  • missing fields;
  • duplicate IDs;
  • protocol deviations.

34.3 Use field paradata

IMAGE experience showed that GPS, timestamps and photographs can reveal whether sampling teams actually moved among plantings as intended.

Potential QA flags include:

  • repeated coordinates for supposedly different fields;
  • implausibly rapid sampling;
  • missing photos;
  • unusually high sample collection rates;
  • duplicated Sample IDs.

Flags should prompt investigation rather than automatic rejection.

35.Daily Reconciliation

At the end of each field day:

Physical samples held = Completed sample records

Any discrepancy should be investigated immediately.

Possible causes include:

  • missing sample;
  • duplicate record;
  • duplicate barcode;
  • damaged envelope;
  • data entry error;
  • sample placed in wrong batch.

IMAGE Nigeria reported improvements in Wave 2 from stronger sample traceability, daily coordination, dashboard monitoring and closer field-laboratory communication.

36.Sample Acceptance

A sample should normally be accepted where:

  • identity is clear;
  • Sample ID links to the correct record;
  • quantity is sufficient;
  • sample type is known;
  • packaging is intact;
  • tissue is sufficiently dry or can be dried further;
  • no major mold or rot is present;
  • contributing-plant requirements were met.
37.Conditional Acceptance

A sample may be retained for corrective action where:

  • further drying is required;
  • packaging needs replacement;
  • minor metadata can be reconciled confidently;
  • desiccant has become exhausted;
  • a small physical issue does not compromise identity.

Identity should never be repaired by guessing.

Any correction should preserve an audit trail.

38.Sample Rejection

Potential rejection reasons include:

  • unresolvable Sample ID;
  • sample cannot be linked to a source record;
  • mold;
  • rot;
  • severe contamination;
  • insufficient tissue;
  • severely damaged packaging;
  • excessive moisture with deterioration;
  • wrong crop or tissue;
  • fewer contributing plants than the protocol requires;
  • known mixing with another sample.

The rejection reason should be recorded rather than simply deleting the sample.

39.Crop-Specific Considerations

39.1 Rice

Possible materials include:

  • leaf;
  • panicle/grain;
  • crop-cut grain;
  • stored grain;
  • mill grain.

Consider:

  • standing crop stage;
  • storage mixing;
  • pooled grain interpretation;
  • need to germinate individual grain for single-plant analysis.

39.2 Common bean and cowpea

Possible materials include:

  • leaf;
  • pods;
  • grain;
  • crop-cut grain.

For expected pure-line materials, individual plants can provide relatively clean genotypes.

39.3 Wheat

Possible materials include:

  • leaf;
  • grain;
  • crop-cut harvest.

Interpretation of heterozygous marker signals requires additional analytical caution because some markers may detect paralogs.

This issue is addressed more fully in the analytical guidance.

39.4 Cassava

Possible materials include:

  • leaf tissue;
  • root tissue.

IMAGE Nigeria demonstrated successful field sampling of single- and multiple-plant leaf material and root sampling at aggregation points.

Root tissue therefore provides a practical option where leaves are unavailable.

39.5 Heterogeneous populations

For crops or varieties where genetic heterogeneity is expected, sample enough plants to represent the population.

Do not interpret within-population diversity automatically as contamination.

40.Common Risks and Controls
RiskControl
Sample taken from wrong plantingVerify Planting ID before collection
Convenient plants selectedUse predefined spatial selection procedure
Single plant interpreted as whole plantingRecord sample representation explicitly
Pooled sample interpreted as genetically pureTreat assignment as population-level evidence
Heterogeneous target represented by one plantUse population sampling
Different plants contribute unequal tissueStandardize approximate contribution
Cutting tools contaminate samplesClean between samples
External label lostUse robust/dual labelling
Barcode does not match digital recordScan and verify in field
Wet tissue moldsBegin drying promptly
Silica becomes exhaustedMonitor and replace
Bag damagedReplace or double-bag
Grain from several fields mixedSample before mixing or flag uncertainty
Stored grain assigned to wrong varietyRecord source confidence and mixing
Phenotype-targeted samples treated as randomStore sampling strategy
Samples retained too long in fieldEstablish transport schedule
Grow-out sample loses linkage to original grain/crop-cut sampleMaintain Parent Sample ID and Planting ID through germination, plant growth, leaf collection and genotyping
Grow-out plants are interpreted as the original individual plants in the fieldInterpret them as individual plants derived from the sampled grain population
Physical and digital sample counts differDaily reconciliation
GPS/photo collected but not reviewedUse paradata QA flags
Country pilot configuration becomes universal ruleLabel crop- and activity-specific numbers as examples
41.Lessons from IMAGE

41.1 Sample identity is as important as tissue quality

A high-quality genotype has limited monitoring value if it cannot be linked confidently to the correct survey, planting or source record.

41.2 Single- and multiple-plant sampling answer different questions

Single plants provide clearer individual genotypes.

Multiple-plant samples provide population-level information.

Neither should be adopted universally.

41.3 Mixture can be a real biological result

Greater ambiguity in pooled samples does not automatically mean poor sampling or laboratory failure.

It may reflect genuine mixture within the sampled population.

41.4 Single plants can also support laboratory QA

Unexpected mixture-like signals in samples that should represent one clean plant can help identify possible:

  • contamination;
  • sample switching;
  • unusual biological events.

41.5 Drying is a critical field operation

Poor preservation can destroy otherwise useful samples.

Silica activity and bag condition should therefore be monitored actively rather than simply placing envelopes in desiccant once.

41.6 Alternative tissue types expand monitoring options

Cassava root sampling demonstrated that monitoring does not always need to depend on leaf availability.

41.7 Aggregation points can be efficient sampling locations

Markets, processors and mills can provide efficient access to material from many growers but support a different inference from field sampling.

41.8 Practical training matters

Nigeria trained enumerators using both classroom instruction and simulated field sampling for leaf and root protocols before deployment.

41.9 Field and laboratory teams should remain connected during implementation

Nigeria Wave 2 identified real-time laboratory engagement, dedicated logistics and dashboard-based monitoring as useful practices for strengthening sample quality and traceability.

42.Context-Dependent Decisions

This guidance does not prescribe one universal:

  • number of single plants;
  • number of plants in a pooled sample;
  • walking pattern;
  • leaf quantity;
  • grain quantity;
  • root section size;
  • silica quantity;
  • number of envelopes per drying bag;
  • sample-transport frequency;
  • preferred tissue type;
  • direct grain genotyping versus grow-out for individual-plant sampling;
  • aggregation-point design;
  • single- versus multiple-plant configuration.

These decisions should follow:

  • monitoring objective;
  • crop biology;
  • sample representation;
  • laboratory requirements;
  • field conditions;
  • available resources.
43.Related Guidance

This guidance should be used with:

Planning and Designing a Genotyped Crop Survey

Defines:

  • monitoring question;
  • sample representation;
  • target population;
  • single/multiple-plant rationale.

Integrating Genotyping into Existing Agricultural Surveys and Crop-Cut Systems

Provides specific guidance where plant material is collected within existing surveys.

Sample Traceability and Laboratory Workflow

Covers:

  • batch handover;
  • laboratory accession;
  • sample processing;
  • backup samples;
  • plate preparation;
  • genotyping shipment.

Developing, Validating and Maintaining a Genetic Reference Library

Provides additional guidance where the samples being collected are reference materials rather than farmer-field survey material.

Analyzing and Reporting Genotyped Crop Survey Results

Addresses:

  • interpretation of pooled versus individual genotypes;
  • mixture diagnostics;
  • heterozygosity;
  • divergence;
  • classification.

45. Evidence and Adaptation

Overall evidence base: Strong operational evidence, with sample composition and crop-specific implementation remaining context-dependent.

Strongly supported through IMAGE experience


The evidence supports:

  • linking every physical sample permanently to the relevant survey/source record;
  • using healthy plant material suitable for DNA extraction;
  • cleaning tools between samples;
  • drying samples promptly;
  • monitoring desiccant activity;
  • maintaining sample identity during transport;
  • daily reconciliation of physical and digital records;
  • interpreting single- and multiple-plant samples according to different biological purposes;
  • using single-plant samples for clearer individual genotypes;
  • using multiple-plant samples for population-level representation;
  • considering target-material homogeneity when choosing sampling strategy;
  • use of leaf, grain and cassava root tissue under appropriate conditions;
  • aggregation-point sampling as a viable alternative monitoring pathway;
  • field QA through GPS, timestamps and photographs.


Evidence-based but context-dependent

The appropriate method depends on crop, objective and operating context for:

  • single- versus multiple-plant sampling;
  • combined sampling;
  • staged sampling;
  • random versus phenotype-targeted sampling;
  • standing crop versus stored grain;
  • field versus aggregation-point sampling;
  • leaf versus grain versus root;
  • number of contributing plants;
  • field-selection route;
  • tissue quantity;
  • preservation configuration.

Should not be treated as universal IMAGE standards

IMAGE does not establish one mandatory:

  • number of plants per pooled sample;
  • number of single plants per planting;
  • W-shaped, zig-zag or other route;
  • tissue quantity;
  • silica-gel quantity;
  • transport frequency;
  • sample container configuration;
  • crop-specific sampling age or stage.


Country and crop protocols used different configurations according to their objectives and operational circumstances.

The guiding principle is:

Define what the sample must represent, collect material in a way that preserves that representation, and protect its identity and biological quality until it reaches the laboratory.

Sample Traceability and Laboratory Workflow

Microsite Summary

A genotyped crop survey depends on maintaining an unbroken link between the physical plant sample, the survey or reference record from which it originated, the laboratory material prepared from it, and the genotype result eventually returned.

The sample journey should therefore be treated as one continuous chain:

Survey/GRL record → Sample ID → Field collection → Field batch → Handover → Laboratory receipt → Accession → Processing → Backup sample → Genotyping order → Shipment → Provider receipt → Genotype result → Link back to source record

A sample can be biologically excellent but have little monitoring value if its identity cannot be established confidently. IMAGE experience showed that identifier and sample-tracking problems can compromise or even prevent linkage of genotype results to socioeconomic, geographic and reference information.

Traceability should therefore be designed before fieldwork begins and maintained through every transfer, processing step and analytical handover.

The central principle is:

Every physical sample, processed aliquot and genotype result should remain traceable to one authoritative Sample ID and the original survey, planting, inventory or reference record from which it came.


1. Introduction and Purpose

This guidance supports institutions developing procedures for:

  • sample identification;
  • field-to-laboratory chain of custody;
  • batch management;
  • sample receipt and accession;
  • acceptance, conditional acceptance and rejection;
  • laboratory processing;
  • contamination prevention;
  • primary and backup sample preparation;
  • tube, rack and plate management;
  • preparation of genotyping orders;
  • shipment to a genotyping provider;
  • confirmation of provider receipt;
  • reconciliation of returned genotype data.


The guidance begins when identifiers and physical sample containers are prepared and continues until genotype results have been linked successfully back to the originating survey or Genetic Reference Library record.

It complements the preceding guidance on Selecting, Collecting and Preserving Plant Material.

It does not prescribe:

  • DNA extraction chemistry;
  • sequencing procedures;
  • marker-panel operation;
  • bioinformatic classification;
  • laboratory quality-management systems beyond the requirements needed to preserve sample identity and integrity.


Those functions should follow the laboratory and genotyping-provider methods in use.

2. Intended Users

This guidance is intended for:

  • survey data managers;
  • field coordinators;
  • enumerators and sampling technicians;
  • field supervisors;
  • transport and submission officers;
  • laboratory receiving officers;
  • laboratory technicians;
  • GRL managers;
  • genotyping coordinators;
  • quality-assurance staff;
  • data managers;
  • institutions shipping samples to external genotyping providers.


The full workflow should be designed jointly.

Traceability should not be treated as the responsibility of only the laboratory or only the field team. 

3.Why Traceability Matters

Genotyped varietal monitoring combines several information systems:

  • household or survey data;
  • planting or field information;
  • physical plant material;
  • laboratory records;
  • genotyping orders;
  • genotype files;
  • GRL information;
  • analytical results.

The Sample ID is the connection among these systems.

If that connection fails, it may become impossible to determine:

  • where a sample came from;
  • which field or planting it represents;
  • what sample type was collected;
  • whether it was single- or multiple-plant material;
  • which laboratory preparation produced a genotype;
  • which genotype belongs to a household;
  • whether the sample is a survey sample or a reference sample.

IMAGE close-out work documented situations where genotypes could not be used confidently because the physical material could not be reconciled reliably with the associated records.

Traceability is therefore a scientific quality requirement, not simply an administrative convenience.

4.Design the Identifier System Before Fieldwork

Minimum requirement

The identifier structure should be defined before sample containers are prepared or field teams are deployed.

At minimum, the system should distinguish:

  • Study or Survey ID;
  • Household/Source ID;
  • Planting, Field, Inventory or Lot ID;
  • Sample ID;
  • Batch ID;
  • laboratory accession or processing identifier where used;
  • genotyping order;
  • plate/rack position where relevant.

The identifier hierarchy should preserve the relationship:

Study → Source → Sampling unit → Physical sample

For survey samples, this may be:

Survey → Household → Crop → Planting → Sample

For GRL material:

GRL study → Variety → Source → Inventory → Sample
5.Use One Authoritative Sample ID

Minimum requirement

Each physical biological sample should have one unique, permanent Sample ID.

That ID should remain associated with the sample through:

  • collection;
  • preservation;
  • transport;
  • laboratory receipt;
  • processing;
  • backup preparation;
  • genotyping submission;
  • genotype output.

Do not change the core identifier merely because the sample enters another institution.

Where laboratories need internal accession numbers, retain a mapping:

Original Sample ID ↔ Laboratory Accession ID

rather than replacing the original identifier.

6.Characteristics of a Good Sample ID

A Sample ID should be:

  • unique;
  • permanent;
  • readable;
  • sufficiently short for practical field and laboratory use;
  • compatible with digital survey systems;
  • compatible with laboratory systems;
  • resistant to transcription errors;
  • usable in spreadsheets and genotype files without truncation or reformatting.

Avoid identifiers that depend only on:

  • respondent names;
  • farmer-reported variety names;
  • spreadsheet row numbers;
  • filenames;
  • position in an un-versioned list.

These can change or be duplicated.

7.Encode Information Carefully

A Sample ID may contain useful structure, for example:

IMAGE-NG-CAS-0048-SP01

where components could represent:

  • project;
  • country;
  • crop;
  • unique sample number;
  • sample type.

However, avoid embedding so much information into the identifier that:

  • IDs become excessively long;
  • field teams mistype them;
  • crop or sample classifications later need to change;
  • the same identifier is interpreted differently by different systems.

The authoritative information should remain in the metadata record rather than relying entirely on interpretation of the ID string.

8.Use Machine-Readable and Human-Readable Labels

Recommended practice

Use both:

  • a barcode or other machine-readable identifier; and
  • a visible human-readable Sample ID.

The machine-readable label reduces manual transcription.

The human-readable identifier provides:

  • visual confirmation;
  • a fallback if the barcode cannot be scanned;
  • support during physical reconciliation.

IMAGE operational materials repeatedly used barcode-based sample tracking.

9.Use Duplicate Labels Where Appropriate

Where envelopes or containers allow it, duplicate identification may be useful.

For example:

  • one external label;
  • one duplicate internal identifier.

This reduces the risk that the sample becomes unidentifiable if the external label:

  • detaches;
  • becomes wet;
  • fades;
  • is damaged during transport.

The field and laboratory procedure should define how duplicate labels are used without creating duplicate samples accidentally.

10.Validate Identifiers Electronically

Where digital survey or laboratory systems are used, configure checks for:

  • duplicate IDs;
  • missing IDs;
  • invalid formats;
  • barcode reuse;
  • mismatched sample type;
  • Sample ID linked to more than one planting;
  • impossible crop/sample combinations.

The system should prevent or flag errors as early as possible.

Correcting one duplicate Sample ID in the field is much easier than reconstructing its identity after genotyping.

11.Link the Sample to Its Source at Collection

Minimum requirement

At the point of collection, the Sample ID should be linked to the correct:

  • survey or study;
  • household/source;
  • crop;
  • planting/field/inventory/lot;
  • farmer- or source-reported variety where relevant;
  • sample type;
  • collection date;
  • collector.

For pooled samples, also record:

  • number of contributing plants;
  • sampling strategy.

For single-plant samples, record the individual sample designation where required.

The basic relationship should remain:

Source record → Sample ID

rather than attempting to reconstruct the source from the genotype file later.

12.Scan and Visually Verify

Recommended practice

Where barcodes are used:

  1. scan the barcode;
  2. confirm the Sample ID displayed digitally;
  3. compare it visually with the physical label;
  4. confirm the correct planting or source record;
  5. collect the material;
  6. close and protect the container.

Scanning alone should not replace visual confirmation because the wrong valid barcode can still be scanned.

13.Track Sample Status Through the Entire Workflow

A useful status sequence is:

  1. Identifier assigned
  2. Collected
  3. Field QC complete
  4. Submitted by field team
  5. Received at laboratory
  6. Accepted
  7. Conditionally accepted
  8. Rejected
  9. Processing started
  10. Processed
  11. Backup retained
  12. Added to genotyping order
  13. Shipped
  14. Received by provider
  15. Genotyping complete
  16. Result received
  17. Result linked to source data
  18. Archived

IMAGE guidance developed this type of end-to-end status model to make it possible to determine where each sample is at any point in the workflow.

Each status should ideally include:

  • date;
  • responsible person;
  • location;
  • remarks where relevant.
14.Organize Samples Into Field Batches

Recommended practice

Samples should move from field teams to receiving facilities in identifiable batches.

Each batch should have a unique Batch ID.

A batch may be organized by:

  • field team;
  • geographic area;
  • crop;
  • collection period;
  • receiving laboratory;
  • another operational unit.

The Batch ID does not replace Sample IDs.

It provides a practical container for managing many individual samples.

15.Prepare a Field Batch Manifest

Every batch should be accompanied by a manifest.

Minimum fields may include:

FieldPurpose
Batch IDIdentifies the shipment/transfer
Sample IDIdentifies each sample
CropConfirms material
TissueLeaf, grain, root, etc.
Sample typeSingle, pooled, etc.
Enumerator/samplerAccountability
ConditionPreliminary QC
RemarksDeviations or issues

The manifest should be generated from the digital sample records wherever possible rather than recreated manually.

16.Reconcile Samples Before Field Handover

Before submitting a batch, the field supervisor should confirm:

  • every physical sample appears on the manifest;
  • every manifest entry has a physical sample;
  • identifiers are readable;
  • no duplicate Sample IDs exist;
  • samples are sufficiently preserved;
  • damaged packages are identified;
  • protocol deviations are recorded.

The core reconciliation is:

Physical samples submitted = valid manifest records

Any discrepancy should be resolved before the batch moves where possible.

17.Record Every Handover

Minimum requirement

Each transfer of custody should be documented.

Examples include:

  • enumerator → supervisor;
  • supervisor → transport officer;
  • transport officer → receiving laboratory;
  • laboratory → courier;
  • courier → genotyping provider.

A handover record should identify:

  • Batch ID;
  • submitting officer;
  • receiving officer;
  • date and time;
  • number expected;
  • number submitted;
  • discrepancies;
  • condition;
  • confirmation of receipt.

IMAGE operational guidance strongly supports explicit handover documentation.

18.Protect Samples During Transport

Transport procedures should maintain:

  • sample identity;
  • packaging integrity;
  • appropriate environmental conditions;
  • separation of batches;
  • security.

Samples should not be transported:

  • loose;
  • without manifests;
  • with unreadable labels;
  • in containers likely to become wet;
  • in conditions incompatible with their preservation method.

The transport officer should not alter sample identifiers.

19.Receive and Reconcile Samples at the Laboratory

Minimum requirement

Laboratory receipt should begin with reconciliation before processing.

The receiving officer should:

  1. confirm Batch ID;
  2. count physical samples;
  3. compare the count with the manifest;
  4. confirm individual Sample IDs;
  5. inspect sample condition;
  6. record discrepancies;
  7. assign acceptance status;
  8. record storage location.

Do not start grinding, subsampling or plate preparation before major identity discrepancies have been resolved.

20.Use a Laboratory Accession Log

The accession record may contain:

Sample IDBatch IDDate receivedConditionDecisionStorage locationProcessing statusRemarks

Where the laboratory uses its own accession number, include both:

  • original Sample ID;
  • laboratory accession number.

The mapping should remain permanent.

21.Classify Samples at Receipt

Samples can be categorized as:

Accepted

The sample is:

  • identifiable;
  • linked to a valid record;
  • of suitable condition;
  • sufficient in quantity;
  • appropriate for processing.

Conditionally accepted

The sample may require:

  • additional drying;
  • relabeling supported by clear evidence;
  • packaging replacement;
  • metadata reconciliation.

Rejected

The sample cannot be used reliably.

Possible reasons include:

  • mold;
  • rot;
  • severe moisture damage;
  • insufficient material;
  • missing label;
  • unresolvable identifier mismatch;
  • missing source record;
  • severe contamination;
  • wrong crop;
  • wrong material;
  • damaged packaging that compromises identity.

IMAGE laboratory guidance recommends identifying poor-quality or untraceable material before investing further processing effort.

22.Do Not Repair Identity by Guessing

Minimum requirement

If a label does not match the record, do not infer the sample identity from:

  • position in the box;
  • crop appearance;
  • neighboring sample numbers;
  • expected sequence;
  • memory.

Investigate using evidence such as:

  • field records;
  • barcode logs;
  • photographs;
  • batch manifests;
  • collector notes.

Where identity cannot be established confidently, reject or quarantine the sample.

23.Maintain an Audit Trail for Corrections

Where a discrepancy can be resolved legitimately, record:

  • original information;
  • corrected information;
  • reason;
  • supporting evidence;
  • person approving the correction;
  • date.

Do not silently overwrite incorrect Sample IDs or metadata.

The audit trail should allow a later reviewer to reconstruct what changed.

24.Provide Feedback to Field Teams

Sample-quality problems should not remain solely within the laboratory.

Feedback should identify patterns such as:

  • wet samples;
  • mold;
  • damaged envelopes;
  • missing labels;
  • duplicate IDs;
  • insufficient tissue;
  • incorrect sample type;
  • incomplete manifests.

Rapid feedback allows field teams to correct procedures while sampling is still underway.

IMAGE country experience showed that stronger field–laboratory communication and traceability improved later implementation.

25.Stabilize Samples Before Processing

After receipt, accepted samples should be maintained under conditions suitable for the material type.

This may include:

  • continued silica drying;
  • additional drying;
  • cool dry storage;
  • another laboratory-approved stabilization approach.

Laboratory teams should confirm that material is ready before:

  • grinding;
  • cutting;
  • transferring;
  • sealing into processing tubes.

Processing incompletely dried material can increase quality and contamination risks.

26.Process Only One Identifiable Sample at a Time

Recommended practice

Laboratory benches should be organized to minimize sample switching.

A technician should verify:

  1. source Sample ID;
  2. destination tube/container;
  3. sample type;
  4. processing step;

before material is transferred.

Where practical:

  • keep only the current sample open;
  • close processed containers before opening the next;
  • organize samples according to the working manifest.
27.Prevent Cross-Contamination During Processing

Minimum requirement

Equipment that contacts biological material should be cleaned between samples.

Depending on the tissue and equipment, this may include:

  • scissors;
  • scalpels;
  • grinders;
  • grinding chambers;
  • forceps;
  • work surfaces.

IMAGE protocols repeatedly used approximately 70–75% ethanol for appropriate cutting tools, while grinding procedures included cleaning between samples.

The laboratory SOP should specify the appropriate cleaning procedure for its equipment.

28.Process Grain Carefully

Where grain is prepared for genotyping, the laboratory may need to:

  • confirm adequate dryness;
  • grind the grain;
  • transfer an appropriate quantity to a tube;
  • retain backup material.

The exact grinding and tissue quantity should follow the genotyping provider’s specifications.

The general requirement is:

the processed material must remain linked unambiguously to the original Sample ID.

Grinders should be cleaned sufficiently between samples to avoid carry-over.

29.Process Leaf and Other Tissue Carefully

For dried leaf or other tissue:

  • verify the Sample ID before opening;
  • take the provider-required amount;
  • transfer it to the correct destination tube;
  • retain original material where required;
  • record the transfer.

Where tissue must be cut or subsampled:

  • use clean equipment;
  • avoid transferring fragments from neighboring samples;
  • close the source envelope after use.
30.Prepare Primary and Backup Samples Deliberately

Recommended practice

Where sufficient material is available, prepare:

  • a primary sample for genotyping;
  • a retained backup.

IMAGE laboratory guidance recommends preparing primary and backup material rather than exhausting the entire sample in one submission.

A backup can support:

  • repeat genotyping;
  • investigation of failed samples;
  • resolution of unexpected analytical results;
  • replacement of lost or damaged shipments.
31.Label Backup Material Clearly

Backup tubes should not create ambiguity with the primary sample.

One approach is to retain the core Sample ID and append a controlled suffix, for example:

  • SAMPLE123-A
  • SAMPLE123-B

or another institutionally defined convention.

The metadata should identify:

  • which is the primary;
  • which is the backup;
  • storage location;
  • date prepared.

Do not create an unrelated new Sample ID that breaks the relationship to the original sample.

32.Define Backup Retention Policy

Context-dependent

Institutions should decide:

  • which samples require backups;
  • minimum retained quantity;
  • storage conditions;
  • storage location;
  • retention duration;
  • conditions for disposal;
  • who can authorize use of the backup.

IMAGE does not establish one universal storage duration.

The policy should reflect:

  • sample value;
  • cost of recollection;
  • expected need for repeat analysis;
  • storage capacity;
  • national institutional requirements.
33.Manage Tubes, Racks and Plates as Traceability Objects

Where samples are transferred into:

  • tubes;
  • racks;
  • 96-well plates;
  • other multi-position formats,

the position becomes part of the chain of custody.

Each transfer should preserve:

Sample ID → Container ID → Position

For example:

IMAGE-018462 → Plate P07 → Well C06

The plate map should be stored electronically and checked before shipment.

34.Do Not Rely on Physical Position Alone

Minimum requirement

A sample must not be identified solely because it is:

“the third tube in row two.”

If tubes shift during handling, positional identity can be lost.

Where possible, individual tubes should also carry:

  • Sample ID;
  • barcode or other machine-readable identifier.

The plate map provides an additional relationship rather than replacing the Sample ID.

35.Verify Every Source-to-Destination Transfer

At each transfer, confirm:

  • source Sample ID;
  • destination ID;
  • rack/plate;
  • well position.

This is a critical quality-control point because a sample switch introduced during plate preparation can generate a technically valid genotype assigned to the wrong field or reference.

IMAGE guidance identifies transfer to tubes or plates as a formal QC checkpoint.

36.Use Controls According to the Laboratory/Provider Method

Where a genotyping platform requires:

  • blanks;
  • reference controls;
  • replicates;
  • control varieties,

their placement should be preserved in the plate map and order documentation.

The number and type of controls should follow the analytical method and provider requirements.

This guidance does not prescribe one universal control configuration.

37.Prepare the Genotyping Order From the Accessioned Sample List

Minimum requirement

The provider order file should be generated from the samples actually prepared for shipment.

Do not prepare the definitive order file only from the original field list because some samples may have been:

  • rejected;
  • conditionally accepted;
  • lost;
  • replaced;
  • not processed.

The final order should correspond exactly to the physical shipment.

38.Minimum Genotyping Order Information

Provider-specific requirements vary, but the order may include:

  • Sample ID;
  • crop/species;
  • tissue type;
  • plate or rack;
  • well position;
  • requested service;
  • project/order reference.

Only information required by the provider should be shared.

The provider generally does not need access to confidential household survey data.

39.Reconcile the Order File, Plate Map and Physical Samples

Minimum requirement

Before shipment, confirm:

Order records = physical shipment samples = plate/rack map

Check for:

  • missing samples;
  • extra samples;
  • duplicate IDs;
  • wrong plate positions;
  • incorrect crop;
  • samples marked rejected but included;
  • backup samples accidentally included as primary samples.

Shipment should not proceed until discrepancies are resolved.

40.Prepare a Shipment Manifest

A shipment manifest may include:

Provider orderPlate/Rack IDWell/PositionSample IDCropTissueBackup retainedRemarks

The shipment package should contain the documentation required by:

  • the laboratory;
  • the courier;
  • the provider;
  • applicable national authorities.
41.Comply With Shipment and Permit Requirements

Context-dependent

Cross-border shipment of biological materials may require:

  • permits;
  • phytosanitary documentation;
  • material-transfer documentation;
  • customs declarations;
  • provider import instructions.

These requirements vary by:

  • country;
  • crop;
  • tissue type;
  • destination;
  • provider.

The project should confirm requirements before the intended shipment date.

IMAGE materials do not establish one universal export or import procedure.

42.Record Shipment Tracking

Record:

  • shipment date;
  • courier;
  • tracking number;
  • sender;
  • destination;
  • provider order;
  • number of plates/racks or samples;
  • expected delivery.

Tracking should be linked to the shipment record rather than maintained only in personal email.

43.Confirm Provider Receipt

Minimum requirement

The chain of custody does not end when samples leave the local laboratory.

Confirm:

  • package received;
  • number of plates/packages received;
  • physical condition;
  • provider order recognized;
  • any missing or damaged material;
  • provider acceptance.

IMAGE traceability guidance explicitly includes confirmation of provider receipt as part of the sample chain.

44.Record Provider Feedback

Provider feedback may include:

  • insufficient tissue;
  • poor DNA quality;
  • failed processing;
  • wrong species;
  • sample contamination;
  • unreadable identifiers;
  • failed genotyping.

These outcomes should be linked back to the Sample ID.

Do not remove failed samples silently from the dataset.

Their status may matter for:

  • non-response analysis;
  • field/laboratory QA;
  • repeat submission;
  • sample-success reporting.
45.Reconcile Returned Genotype Files

Minimum requirement

When genotype results are returned:

  1. identify all returned Sample IDs;
  2. compare them with the submitted order;
  3. identify missing results;
  4. identify unexpected IDs;
  5. identify duplicates;
  6. record failed samples;
  7. confirm that Sample IDs join correctly to the source metadata.

The chain is complete only when the genotype result can be linked confidently to its original sample record.

IMAGE guidance treats result reconciliation as the final chain-of-custody checkpoint.

46.Preserve Raw Provider Identifiers

Where the provider modifies, prefixes or otherwise formats IDs, retain:

  • original submitted Sample ID;
  • provider-returned ID;
  • explicit mapping between them.

Do not permanently replace the project identifier with the provider’s internal representation.

47.Maintain a Sample-Status Tracker

Recommended practice

A central tracker should make it possible to answer:

  • Was the sample collected?
  • Where is it?
  • Was it accepted?
  • Was it processed?
  • Is a backup available?
  • Was it shipped?
  • Did the provider receive it?
  • Did genotyping succeed?
  • Has the result been linked to the survey or GRL dataset?

IMAGE traceability guidance proposes this type of status tracking as a core operational tool.

48.Separate Physical Status From Analytical Classification

Do not use the same field to describe:

Physical workflow status

Examples:

  • received;
  • accepted;
  • rejected;
  • shipped;
  • genotype failed.

and:

Analytical classification

Examples:

  • Matched-Unique;
  • Group;
  • Genetic Entity;
  • Unidentified.

These describe different processes and should remain separate in the data model.

49.Roles and Responsibilities

Survey data manager

Responsible for:

  • identifier structure;
  • barcode validation;
  • duplicate prevention;
  • survey-to-sample linkage;
  • audit trails.

Enumerator or sampler

Responsible for:

  • verifying identifiers;
  • correct labelling;
  • recording sample type;
  • protecting material;
  • reporting deviations.

Field supervisor

Responsible for:

  • daily reconciliation;
  • manifests;
  • field discrepancy resolution;
  • batch preparation.

Transport/submission officer

Responsible for:

  • secure transport;
  • signed handovers;
  • delivery to laboratory.

Receiving laboratory officer

Responsible for:

  • receipt;
  • count reconciliation;
  • condition assessment;
  • acceptance/rejection;
  • storage assignment.

Sample-processing officer

Responsible for:

  • processing;
  • contamination prevention;
  • backup preparation;
  • tube/rack/plate mapping.

Genotyping coordinator

Responsible for:

  • provider orders;
  • shipment documentation;
  • delivery confirmation;
  • provider feedback;
  • reconciliation of returned results.

These functions may be combined in smaller programs, but responsibilities should remain explicit.

50.Quality-Control Checkpoints

The workflow should include formal checkpoints.

Checkpoint 1 — Identifier assignment

Confirm:

  • uniqueness;
  • correct format;
  • readable barcode;
  • correct label.

Checkpoint 2 — Field collection

Confirm:

  • correct sample/source linkage;
  • barcode scanned;
  • sample type recorded;
  • container protected.

Checkpoint 3 — Daily field reconciliation

Confirm:

  • physical samples equal digital records;
  • no duplicates;
  • no unlabeled samples;
  • preservation acceptable.

Checkpoint 4 — Laboratory receipt

Confirm:

  • count;
  • manifest;
  • identity;
  • condition;
  • acceptance status.

Checkpoint 5 — Processing transfer

Confirm:

  • source Sample ID;
  • destination tube;
  • plate/rack position;
  • tools cleaned.

Checkpoint 6 — Pre-shipment

Confirm:

  • physical samples match order file;
  • plate map complete;
  • shipment documents ready;
  • backups recorded.

Checkpoint 7 — Result receipt

Confirm:

  • returned IDs reconcile;
  • failed samples identified;
  • genotype data join successfully to source metadata.

These checkpoints reflect the workflow developed from IMAGE sample-handling experience.

51.Common Risks and Controls
RiskControl
Duplicate Sample IDsElectronic uniqueness validation
Barcode attached to wrong sampleScan and visual verification at collection
Sample and digital record disagreeResolve before field handover
Samples go missing between field and labBatch manifest and signed handover
Laboratory accepts untraceable sampleQuarantine/reject unresolved IDs
Wet or moldy samples processed unnecessarilyCondition assessment at receipt
Sample identity guessed from physical sequenceRequire evidence-based reconciliation
Corrections overwrite original informationMaintain audit trail
Samples switch during grinding or transferOne-sample-at-a-time workflow and destination verification
Cross-contamination during processingClean equipment between samples
Backup and primary confusedControlled suffix and metadata
Tubes shift in rackIndividual Sample ID + position map
Plate map differs from provider orderPre-shipment reconciliation
Rejected samples remain in order fileBuild order from accepted processed samples
Shipment arrives damagedRecord tracking and provider receipt condition
Provider changes ID formattingMaintain submitted-to-returned ID crosswalk
Failed genotypes disappear from final datasetRetain failure status
Genotype cannot be linked to survey dataFinal returned-ID reconciliation
Multiple institutions maintain conflicting sample listsEstablish one authoritative status tracker
52.Lessons from IMAGE

52.1 Traceability is a scientific requirement

A genotype without a reliable source link cannot support credible varietal-monitoring interpretation.

52.2 Errors should be detected as early as possible

Identifier problems identified:

  • in the field are easiest to resolve;
  • at laboratory receipt are harder;
  • after genotyping may be impossible to resolve confidently.

52.3 Physical and digital records should be reconciled repeatedly

Reconciliation should happen:

  • daily in the field;
  • at every handover;
  • at laboratory receipt;
  • before shipment;
  • when results return.

52.4 The chain continues beyond the local laboratory

Shipping samples successfully is not the endpoint.

Provider receipt and returned genotype reconciliation are part of the same chain.

52.5 Backup material reduces operational risk

Where sufficient sample material exists, retaining a backup provides an option when:

  • shipment is lost;
  • genotyping fails;
  • results require confirmation.

52.6 Laboratory processing can introduce identity errors

A perfectly tracked field sample can still be compromised by:

  • tube switching;
  • plate-map errors;
  • contamination;
  • incorrect order files.

Traceability must therefore continue through processing.

52.7 Rapid field–laboratory feedback improves implementation

IMAGE country experience showed that stronger traceability and closer coordination reduced reconciliation effort and supported faster resolution of problems.

52.8 Returned genotype data require a final custody check

Successful technical genotyping does not by itself confirm that the result is linked correctly.

The returned Sample ID must reconcile with the original source data.

53.Context-Dependent Decisions

This guidance does not prescribe one universal:

  • Sample ID format;
  • barcode technology;
  • barcode standard;
  • Batch ID structure;
  • frequency of field-to-lab transfer;
  • laboratory accession numbering system;
  • backup quantity;
  • backup-storage period;
  • processing-tube format;
  • rack or plate configuration;
  • electronic versus paper handover signature;
  • courier;
  • shipment permit process;
  • provider-order format.

These should be adapted to:

  • survey software;
  • field connectivity;
  • laboratory information systems;
  • crop and tissue type;
  • sample volume;
  • genotyping provider;
  • institutional data systems;
  • national regulations.

The underlying traceability principles should remain constant even where the technology differs.

54.Minimum Records to Retain

At the completion of the workflow, the project should retain at least:

  1. Sample-ID specification
  2. Survey/sample linkage dataset
  3. Field sample records
  4. Batch manifests
  5. Handover records
  6. Laboratory accession log
  7. Acceptance/rejection records
  8. Correction and discrepancy log
  9. Processing records
  10. Backup-sample register
  11. Rack/plate maps
  12. Genotyping order files
  13. Shipment manifests
  14. Courier/tracking records
  15. Provider receipt confirmation
  16. Provider sample-quality feedback
  17. Returned genotype files
  18. Submitted-to-returned ID mapping where needed
  19. Final sample-status tracker

These records collectively provide the audit trail from field collection to analytical data.

55.Related Guidance

This guidance should be used with:

Planning and Designing a Genotyped Crop Survey

Defines the survey identifier hierarchy and intended survey-to-sample linkage.

Selecting, Collecting and Preserving Plant Material

Covers:

  • physical sampling;
  • sample type;
  • preservation;
  • field QA;
  • initial labelling.

Integrating Genotyping into Existing Agricultural Surveys and Crop-Cut Systems

Explains how Sample IDs should coexist with existing national survey identifiers.

Developing, Validating and Maintaining a Genetic Reference Library

Applies the same traceability principles to reference materials and inventories.

GRL Metadata and Tracking Standard

Defines the persistent metadata relationships for reference varieties, sources, inventories and genotype profiles.

Analyzing and Reporting Genotyped Crop Survey Results

Uses the final reconciled Sample IDs to link genotype classifications back to survey and reference data.

56.Tools & Downloads

The guide includes field sample-collection and preservation checks, contamination prevention, sample-identification requirements and field-to-laboratory handover procedures. The workbook provides the corresponding operational records.

55. Related Guidance

This guidance should be used with:

Planning and Designing a Genotyped Crop Survey

Defines the survey identifier hierarchy and intended survey-to-sample linkage.

Selecting, Collecting and Preserving Plant Material

Covers:

  • physical sampling;
  • sample type;
  • preservation;
  • field QA;
  • initial labelling.


Integrating Genotyping into Existing Agricultural Surveys and Crop-Cut Systems

Explains how Sample IDs should coexist with existing national survey identifiers.

Developing, Validating and Maintaining a Genetic Reference Library

Applies the same traceability principles to reference materials and inventories.

GRL Metadata and Tracking Standard

Defines the persistent metadata relationships for reference varieties, sources, inventories and genotype profiles.

Analyzing and Reporting Genotyped Crop Survey Results

Uses the final reconciled Sample IDs to link genotype classifications back to survey and reference data. 

IMAGE Sample Collection, Traceability & Laboratory Workflow GuideIMAGE Sample Tracking & Laboratory Workflow Workbook

The guide includes field sample-collection and preservation checks, contamination prevention, sample-identification requirements and field-to-laboratory handover procedures. The workbook provides the corresponding operational records.

57. Evidence and Adaptation

Overall evidence base: Strong operational evidence from IMAGE field, laboratory and genotyping workflows.

Strongly supported through IMAGE experience


The available evidence supports:

  • unique permanent Sample IDs;
  • machine-readable and human-readable identifiers;
  • physical-to-digital sample linkage;
  • batch manifests;
  • repeated physical/digital reconciliation;
  • documented handovers;
  • laboratory accessioning;
  • explicit acceptance and rejection;
  • contamination prevention during processing;
  • preparation of backup samples where practical;
  • tube/rack/plate position tracking;
  • reconciliation of physical shipment with provider order files;
  • shipment tracking;
  • confirmation of provider receipt;
  • reconciliation of returned genotype IDs with original source records.


Evidence-based but institution-dependent

Institutions should determine:

  • exact identifier syntax;
  • barcode technology;
  • accession system;
  • transfer frequency;
  • backup-retention policy;
  • plate organization;
  • laboratory software;
  • electronic versus paper signatures;
  • sample-storage duration.


Should not be treated as universal IMAGE standards

IMAGE does not establish one mandatory:

  • barcode format;
  • Sample ID prefix;
  • shipment frequency;
  • laboratory accession platform;
  • number of backup aliquots;
  • backup-storage duration;
  • plate layout;
  • courier;
  • permit process;
  • provider-order format.


The guiding principle is:

At every stage, an independent reviewer should be able to determine what the sample is, where it came from, what happened to it, where it is now, and which genotype result was generated from it. 

Survey Execution

Turn design into reliable, high-quality data and samples.


Survey execution is where the VMG system meets reality. It is the translation of a statistically sound design into consistent, field-level action. Every interaction, measurement, and sample collected determines whether the system produces credible results.

Strong execution is not just about completing surveys. It is about discipline, consistency, and precision across teams, geographies, and time..

Core Components of Survey Execution.

Field Team Preparation
Execution starts before entering the field. Enumerators must be trained, aligned on protocols, and equipped with the right tools. Consistency in how questions are asked, how samples are collected, and how data is recorded is critical to comparability.

Household Interviews
Conduct structured interviews using standardized questionnaires. Maintain neutrality, follow question order, and ensure clarity in responses. The quality of data depends directly on interviewer discipline and respondent trust.

Plot Identification and Verification
Work with respondents to accurately identify plantings. A planting is a contiguous area of a single variety. Misidentification at this stage introduces downstream error that cannot be corrected later.

GPS and Plot Measurement
Capture precise geographic data to define plot boundaries and enable spatial analysis. GPS points should be collected systematically to ensure accuracy and reproducibility.

Plant and Grain Sampling
Collect plant material in a way that represents the true variation of the plot. This requires sampling from multiple plants, avoiding edges, and following structured movement patterns such as diagonal transects.

Sample Labelling and Tracking
Each sample must be uniquely identified and linked to survey data. Labelling errors break the system. Clear identifiers, duplication (inside and outside containers), and alignment with tracking files are essential.

Sample Handling and Storage
Maintain sample integrity from collection through transport. This includes drying, avoiding contamination, and storing in controlled conditions to preserve DNA quality.

From Field to System.

Survey execution connects directly to every other part of VMG. Poor execution weakens genotyping accuracy and undermines analysis. Strong execution creates a clean pipeline from field observation to DNA-based identification to reporting..

This includes:

  • Clean handoff between survey data and sample tracking
  • Alignment between field protocols and lab requirements
  • Continuous quality control through supervision and review

Survey Execution

Selecting, Collecting and Preserving Plant Material

Microsite Summary

Plant-material sampling is the point at which the statistical survey is converted into a biological sample for genotyping.

A good sampling protocol must ensure that the physical sample:

  • represents the biological unit defined in the survey design;
  • is linked unambiguously to the correct household, planting, field, inventory or aggregation source;
  • preserves individual-plant identity where required;
  • captures population-level composition where that is the objective;
  • remains free from avoidable contamination;
  • is dried and preserved adequately;
  • can be traced through laboratory processing and genotyping.

IMAGE experience shows that there is no single best material or sample composition for every crop survey. Leaf, grain and root tissue can all be useful under different circumstances, and single-plant and multiple-plant samples answer different biological questions.

The central principle is:

Collect the material that best represents the biological unit the monitoring question is intended to measure, and preserve its identity and quality from the moment it is sampled.

1. Introduction and Purpose

This guidance supports teams developing field procedures for selecting, collecting and preserving plant material for genotyped crop surveys.

It addresses:

  • deciding what physical material to collect;
  • selecting plants within a planting;
  • single-plant and multiple-plant sampling;
  • homogeneous and heterogeneous target materials;
  • leaf, grain and root sampling;
  • sampling standing crops and stored material;
  • aggregation-point sampling;
  • avoiding contamination;
  • drying and preservation;
  • wet-weather handling;
  • field quality assurance;
  • sample acceptance and rejection;
  • preparing samples for transfer to the laboratory.

The guidance is intended to complement the broader Planning and Designing a Genotyped Crop Survey chapter. The survey design should already have defined:

  • the monitoring question;
  • target population;
  • selected planting, field, inventory or lot;
  • intended level of inference;
  • what the physical sample should represent.

The sampling team should implement that design rather than redefine it in the field.

IMAGE field protocols emphasised three basic requirements:

1. samples must be labelled so that they can be matched to other records;

2. samples must be collected in a form that can be dried and preserved appropriately;

3. where individual plants or a specified number of plants are being sampled, the

material must remain traceable to the intended plant or plant population.

2. Intended Users

This guidance is intended for:

  • field coordinators;
  • crop-sampling teams;
  • agricultural survey enumerators;
  • crop scientists;
  • breeders;
  • seed inspectors;
  • laboratory coordinators;
  • GRL teams;
  • supervisors;
  • varietal-monitoring programmes;
  • organisations commissioning genotyped surveys.

Laboratory and analytical teams should also contribute to protocol development because field sampling choices affect:

  • DNA extraction;
  • sample processing;
  • genotype quality;
  • interpretation of mixtures;
  • analytical assignment.
3. Begin With What the Sample Is Intended to Represent

Minimum requirement

Before collecting material, state what each physical sample is intended to represent.

Possible units include:

  • one individual plant;
  • several plants within one planting;
  • the combined population within a planting;
  • crop-cut harvest;
  • stored grain associated with one planting;
  • a seed or planting-material lot;
  • a reference variety;
  • material entering an aggregation point.

The sample should not later be interpreted more broadly than the collection method allows.

For example:

A single plant represents one individual genotype.

It does not automatically represent the dominant genotype of the full planting.

Likewise:

A pooled sample represents the combined genotype of the sampled population.

It does not necessarily mean that every plant contributing to that population has the same genotype.

IMAGE close-out analysis confirmed that single- and multiple-plant samples from the same planting often generate different genetic assignments, particularly where mixtures are present.

4. Select the Sampling Strategy According to the Monitoring Question

A practical decision framework is:

Monitoring objective Suitable sampling approach
Identify individual genotypes Single-plant sampling
Describe genetic material occurring across the landscape Single plants distributed across plantings
Assess whether a planting population corresponds substantially to a target material Multiple-plant pooled sample
Detect mixture within a planting Several single plants, possibly alongside a pooled sample
Characterise a seed or inventory population Population-level sample
Link genotype with crop-cut yield Crop-cut population sample
Detect distinct material suggested by visible differences Phenotype-targeted single plants
Screen efficiently and investigate mixture later Staged pooled + single-plant approach

There is no universal preferred approach.

5. Single-Plant Sampling

A single-plant sample represents the genotype of one individual plant.

Recommended where the objective is to:

  • identify individual genetic components;
  • investigate genetic diversity within plantings;
  • detect minority genotypes;
  • obtain clean reference genotypes;
  • investigate possible laboratory mixture;
  • sample target materials expected to be genetically homogeneous at individual-plant level. IMAGE close-out analysis showed that single-plant samples generally produce clearer and less ambiguous genotype profiles than multiple-plant samples.

5.1 Important limitation

A clear genotype does not necessarily mean the plant is representative of the planting.

A randomly selected plant could be:

  • the dominant genotype;
  • a minority component of a mixture;
  • an outcrossed individual;
  • a segregating plant.

Single-plant results should therefore be interpreted according to the sampling design.

6. Multiple-Plant Sampling

A multiple-plant sample combines material from several plants into one physical sample.

It can provide an efficient estimate of the population genotype being grown.

Useful where the objective is to:

  • assess whether a planting broadly corresponds to a known target material;
  • characterise the genetic composition of a planting population;
  • characterise a seed or inventory lot;
  • capture mixture without genotyping many individual plants;
  • reduce genotyping cost.

IMAGE field protocols included multi-plant sampling, with the exact number of plants varying across crops and pilots. These numbers should therefore be treated as project- specific configurations rather than universal standards.

6.1 Mixture is not automatically poor sample quality

Where several genetically different plants contribute to a pooled sample, the resulting genotype may show greater ambiguity. In crops where homozygosity is expected, this can appear as higher levels of heterozygous marker calls.

IMAGE close-out analysis demonstrated this pattern consistently across several crops.

The ambiguity can be biologically informative because it reflects the population sampled.

7. Homogeneous Versus Heterogeneous Target Materials

Minimum design decision

Ask:

Is the target material expected to have a relatively homogeneous individual-plant genotype, or is genetic heterogeneity part of the expected variety?

7.1 Expected homogeneous materials

For materials such as:

  • clonal crops;
  • pure-line varieties;
  • highly inbred materials,

single-plant samples can provide useful identity information.

IMAGE applied single-plant sampling to crops including cassava, rice, bean, wheat, tef and cowpea where this logic was appropriate.

7.2 Expected heterogeneous materials

For genetically heterogeneous populations, such as some open-pollinated materials:

  • one plant cannot adequately represent the target variety;
  • population-level sampling is required;
  • observed heterogeneity should not automatically be interpreted as contamination.

The field protocol should therefore reflect the biological structure expected of the crop and target material.

8. Combined Single- and Multiple-Plant Sampling

Where both population identity and individual genetic components are important, both sample types may be collected.

For example:

  • one pooled sample from several plants;
  • one or more individual plants from the same planting.

The Sample IDs must remain distinct but linked to the same Planting ID.

The two sample types should not be treated as interchangeable laboratory replicates.

They answer different questions.

IMAGE Nigeria's cassava pilot used both single-plant and multiple-plant leaf samples from fields, with each sample assigned a unique barcode linked to the field record.

9. Random and Phenotype-Targeted Single-Plant Sampling

Single plants may be selected in different ways.

9.1 Random single-plant sampling

Use where the objective is to describe:

  • individual genotype occurrence;
  • variation across the landscape;
  • variation among plants without visual preselection.

Plants should be selected without favouring:

  • vigour;
  • plant size;
  • apparent health beyond minimum sample-quality requirements;
  • expected variety identity.

9.2 Phenotype-targeted single-plant sampling

A plant may instead be deliberately selected because it appears different from surrounding plants.

This can be useful when the objective is: to maximise the probability of detecting genetically different components within a planting.

IMAGE cassava innovation work used this targeted strategy as part of within-field investigation.

Important limitation

Phenotype-targeted plants are purposively selected.

They should not be interpreted as random representatives of the planting.

The sampling strategy should therefore be recorded in the sample metadata.

10. Consider a Staged Sampling Approach

Context-dependent

Where genotyping cost is a constraint, a staged approach may be used.

One example is:

1. collect a pooled population sample;

2. retain individually identifiable plant material;

3. genotype the pooled sample first;

4. evaluate evidence of mixture or ambiguity;

5. genotype individual samples only where further resolution is needed.

This can reduce the number of individual samples genotyped.

However, it increases:

  • field preparation;
  • storage requirements;
  • identifier complexity;
  • turnaround time;
  • risk that retained samples become unusable.

It should therefore be planned before fieldwork rather than improvised after pooled results are received.

11. Select the Tissue or Material Type

IMAGE sampling work used several material types.

The most relevant include:

  • leaf tissue;
  • grain;
  • cassava root tissue.

The choice should consider:

  • crop stage;
  • intended biological unit;
  • laboratory requirements;
  • ease of preservation;
  • ability to maintain plant identity;
  • availability during the survey;
  • whether stored material has been mixed.

The laboratory or genotyping provider should confirm that the proposed material is compatible with the extraction method before field deployment.

12. Leaf Tissue

Leaf tissue is often advantageous because it can be sampled directly from identified plants.

IMAGE field guidance notes that leaf material can be traced to specific plants and is generally straightforward to prepare for DNA extraction.

12.1 Select suitable tissue

Select tissue that is:

  • healthy;
  • sufficiently developed;
  • green;
  • not heavily damaged;
  • free from obvious disease where possible;
  • not extensively dried or senescent.

Avoid:

  • rotten tissue;
  • severely diseased tissue;
  • scorched leaves;
  • dead or very old leaves;
  • excessively wet or muddy material where a better plant is available.

12.2 Crop-specific tissue specifications

The exact:

  • leaf position;
  • leaf length;
  • amount of tissue;
  • number of leaf pieces

should be defined in a crop-specific field SOP.

IMAGE materials include crop- and activity-specific examples but do not establish one universal tissue quantity.

For example, a later AfricaRice sampling protocol used healthy single plants and three well-expanded leaves at least 5 cm long for that specific GRL activity. This illustrates the type of crop-specific specification that should accompany the generic guidance rather than becoming a universal crop-survey standard.

13. Select Plants Across the Planting

Minimum requirement

Where several plants contribute to the sample, they should represent the defined sampling area rather than being selected only for convenience. Avoid collecting all material from:

  • the field entrance;
  • one corner;
  • consecutive plants;
  • one row;
  • plants closest to the enumerator.

IMAGE protocols used approaches such as:

  • spatially distributed selection;
  • systematic movement;
  • zig-zag or W-shaped routes;
  • plant intervals.

The specific walking pattern can be adapted to the crop and planting structure.

The underlying principle is:

Spread contributing plants across the intended sampling area.

14. Avoid Field Margins Where Appropriate

Recommended practice

Where feasible, avoid relying heavily on plants located at the outer edge of the planting.

Edge plants may differ because of:

  • neighbouring varieties;
  • cross-pollination exposure;
  • management;
  • soil conditions;
  • grazing or damage;
  • different planting density. However, field shape and smallholder planting structure may make strict edge exclusion impractical.

The field SOP should favour representative spatial coverage rather than prescribe one universal edge distance.

15. Leaf Collection Procedure

A general leaf-sampling workflow is:

1. Confirm the correct household, field and planting.

2. Confirm the Sample ID.

3. Confirm sample type: single plant or multiple plant.

4. Select the intended plant.

5. Select suitable healthy tissue.

6. Use clean cutting equipment.

7. Collect the specified tissue quantity.

8. Place the tissue immediately into the correct labelled envelope.

9. Verify the physical label against the digital record.

10. Close the envelope.

11. Place it promptly with active desiccant.

12. Clean cutting equipment before collecting the next sample.

IMAGE Tanzania protocols used labelled paper envelopes, silica gel, resealable bags and cleaned cutting tools.

16. Prevent Cross-Contamination

Minimum requirement

Tools and contact surfaces should be cleaned between samples where there is a reasonable risk of transferring plant tissue.

IMAGE protocols used approximately 70--75% ethanol for cleaning cutting instruments. Controls may include:

  • clean scissors or scalpels;
  • ethanol;
  • clean wipes;
  • clean gloves;
  • clean work surfaces;
  • immediate packaging.

Avoid:

  • placing samples directly on soil;
  • placing tissue from several samples on one surface;
  • reusing contaminated wipes;
  • allowing loose plant fragments to remain in the envelope or work area.
17. Grain Sampling

Grain may be collected:

  • from standing mature plants;
  • crop-cut harvests;
  • household storage;
  • mills or other aggregation points.

Each source supports different inference.

IMAGE sampling guidance notes that grain can provide flexible access to material but may require more processing than leaf tissue, particularly where single grains must be germinated to obtain leaf tissue.

18. Grain From Standing Crops

Where grain remains associated with identifiable plants:

  • individual-plant identity can potentially be retained;
  • grain can be collected from several spatially distributed plants;
  • individual and pooled samples can be constructed deliberately.

The protocol should define:

  • number of contributing plants;
  • number of grain units per plant;
  • whether individual plants remain separate;
  • whether pooled material should contain approximately equal contribution from each plant.

Avoid collecting multiple grain units from one plant and treating them as though they represent several plants.

19. Grain From Crop-Cut Harvests

Crop-cut material represents several plants within a defined crop-cut area.

It may be particularly useful where the survey seeks to connect:

  • genotype;
  • field area;
  • yield;
  • household information.

However:

  • individual-plant identity is lost;
  • mixture may occur;
  • the sample should be interpreted as population-level material.

The crop-cut sample should remain separately identifiable from other harvest material until the genotype subsample is taken.

20. Stored Grain

Context-dependent

Stored grain can be convenient where standing crops are no longer available.

Before sampling, determine:

  • whether grain from different fields has been combined;
  • whether several varieties were mixed;
  • whether the farmer stores varieties separately;
  • whether grain remains attached to ears, pods or panicles;
  • whether the material can be linked confidently to the selected planting.

IMAGE guidance specifically notes that stored grain can become mixed in ways that prevent individual varieties from being distinguished.

If the source cannot be reconstructed, record the sample as:

  • mixed;
  • uncertain;
  • aggregation lot;

rather than assigning a false field or variety identity.

21. Individual-Grain Sampling

Where individual-grain genotypes are required, additional operational steps may be needed.

Depending on the laboratory method:

  • grain may be ground directly;
  • individual seed may need to be germinated;
  • leaf tissue may then be collected from the resulting plant.

IMAGE discussions highlighted that germinating seed before leaf sampling adds:

  • time;
  • labour;
  • handling steps;
  • opportunity for sample switching or contamination. The potential information value should therefore justify the additional complexity.
22. Cassava Root Sampling

IMAGE Nigeria demonstrated that cassava root tissue can be successfully collected and genotyped.

This is particularly useful where:

  • leaf material is unavailable;
  • cassava roots are encountered at processors or markets;
  • monitoring occurs after harvest.

The Nigeria innovation pilot collected silica-dried cassava root samples from aggregation points across six states and successfully processed them for genotyping.

22.1 General root-sampling principles

The sample should be:

  • from a clearly identified root or lot;
  • free from excessive soil;
  • prepared with clean cutting equipment;
  • sampled from suitable internal tissue;
  • dried rapidly;
  • labelled immediately.

Provider instructions used during IMAGE included rinsing and drying the root, cleaning the scalpel with approximately 70% ethanol before each specimen, cutting a thin section and removing brown external skin.

Exact section size and processing should follow the laboratory/provider SOP in use.

23. Aggregation-Point Sampling

Context-dependent

Aggregation points may include:

  • mills;
  • markets;
  • processors;
  • collection centres;
  • storage facilities.

IMAGE pilots demonstrated that these sites can provide efficient access to many samples.

Nigeria collected cassava root material from markets and processing centres, while Tanzania piloted rice sampling at mills. IMAGE close-out findings supported aggregation- point sampling as a viable monitoring pathway where the inference is defined appropriately.

23.1 Preserve source information where possible

Record:

  • aggregation-point ID;
  • location;
  • date;
  • material type;
  • grower/source identity where available;
  • lot or sack identifier;
  • claimed variety;
  • geographic origin;
  • whether material appears mixed.

23.2 Interpretation limitation

An aggregation-point sample represents material entering that part of the value chain.

It should not automatically be interpreted as representative of:

  • all farmers;
  • national planting area;
  • all material grown in the surrounding region.
24. Label Samples Immediately

Minimum requirement

Every sample should be labelled before or at the moment material is placed into its container.

Do not collect multiple unlabeled samples and label them later.

A good Sample ID system should be:

  • unique;
  • permanent;
  • human-readable;
  • machine-readable where possible.

IMAGE protocols used labelled envelopes and barcode-based linkage between physical samples and field data.

25. Use Dual Labelling Where Practical

Recommended practice

Where paper envelopes are used, include identifier information:

  • outside the envelope;
  • and inside where the protocol supports this.

Tanzania field protocols explicitly used matching internal and external labels.

This provides protection if an external label:

  • detaches;
  • becomes wet;
  • fades;
  • is damaged.
26. Minimum Sample Metadata

Each sample record should include at least:

Field Requirement
Sample ID Mandatory
Planting/source ID Mandatory
Crop Mandatory
Tissue/material type Mandatory
Single/multiple/other sample type Mandatory
Number of contributing plants Required for pooled samples
Sampling strategy Recommended
Collection date Mandatory
Collector Mandatory
Sample condition Mandatory
Batch ID Before handover
GPS Context-dependent
Photograph reference Context-dependent
Observed mixture Where relevant
Protocol deviation Where relevant

The metadata should be recorded digitally where possible and linked through the permanent Sample ID.

27. Dry Samples Promptly

Minimum requirement

Samples requiring desiccation should be placed with active drying material as soon as practical after collection. IMAGE protocols commonly used silica gel in resealable plastic bags containing paper sample envelopes.

Effective drying depends on:

  • adequate desiccant;
  • sufficient contact with air around the envelope;
  • bag integrity;
  • avoiding overcrowding;
  • monitoring desiccant condition;
  • replacing exhausted desiccant.
28. Use Active Silica Gel

Where indicator silica is used, the team should understand the colour change indicating moisture absorption.

IMAGE Tanzania protocols used silica that changed from blue to pink as it absorbed moisture and instructed teams to replace it when necessary. Samples were monitored frequently because drying failure could compromise sample integrity.

The exact:

  • silica quantity;
  • number of envelopes per bag;
  • replacement interval

should be defined according to sample type, ambient humidity and field conditions.

A later rice reference-sampling protocol, for example, used approximately 150 g of silica for up to three envelopes under specified conditions. That is an activity-specific example rather than a universal standard.

29. Protect the Drying Container

Minimum requirement

Resealable bags or drying containers should remain:

  • intact;
  • closed;
  • dry;
  • away from direct sun;
  • away from excessive heat.

IMAGE protocols instructed teams to check for holes or damaged bags because moisture entering the container can reduce drying effectiveness.

Where damaged:

  • replace the bag;
  • or double-bag temporarily until material can be transferred safely.
30. Wet-Weather Sampling

Recommended practice

Avoid collecting plant tissue during heavy rain where the survey design and timing permit.

Where wet tissue must be sampled:

  • remove excess surface water gently;
  • use clean material to blot moisture;
  • place tissue promptly in the labelled envelope;
  • start desiccation immediately;
  • monitor the sample more frequently;
  • replace desiccant as needed.

Wet tissue is at higher risk of:

  • fungal growth;
  • rot;
  • poor drying;
  • sample rejection. The field protocol should include a wet-weather contingency rather than leaving enumerators to improvise.
31. Store Samples in a Cool, Dry Environment

Until transfer to the laboratory, samples should be stored:

  • out of direct sunlight;
  • away from rain and humidity;
  • away from excessive heat;
  • protected from rodents and insects;
  • organised by batch.

IMAGE Tanzania protocols recommended a cool, dry room or space with relatively stable temperature.

Avoid prolonged sample storage:

  • inside hot vehicles;
  • in wet bags;
  • exposed outdoors;
  • in unventilated humid rooms.
32. Transport Samples Frequently

Recommended practice

Do not retain field samples longer than necessary once they can be moved safely to the receiving laboratory.

Transport frequency should consider:

  • preservation system;
  • field location;
  • crop material;
  • laboratory capacity;
  • transport cost.

IMAGE Tanzania protocols used regular scheduled transfer to TOSCI, supported by submission reports and supervisor oversight.

The precise frequency was operationally specific and should not become a universal IMAGE rule.

33. Use a Batch Handover Record

Every transfer should be associated with a Batch ID.

The handover record should include:

  • submitting officer;
  • receiving officer;
  • date;
  • crop;
  • tissue type;
  • Sample ID range or list;
  • number expected;
  • number transferred;
  • sample condition;
  • remarks.

The submitting and receiving persons should reconcile physical and digital sample counts.

Detailed laboratory accession is addressed in the companion Sample Traceability and Laboratory Workflow guidance.

34. Field Quality Assurance

Minimum requirement

Quality checks should occur while sampling is still underway.

34.1 Sampler self-check

Before leaving the planting or source, confirm:

  • correct source;
  • correct crop;
  • correct Sample ID;
  • correct sample type;
  • required number of contributing plants;
  • adequate tissue;
  • physical and digital identifiers agree;
  • sample placed in desiccant;
  • required GPS/photo recorded.

34.2 Supervisor review

Supervisors should review:

  • physical sample count;
  • Sample IDs;
  • preservation condition;
  • desiccant activity;
  • missing fields;
  • duplicate IDs;
  • protocol deviations.

34.3 Use field paradata

IMAGE experience showed that GPS, timestamps and photographs can reveal whether sampling teams actually moved among plantings as intended.

Potential QA flags include:

  • repeated coordinates for supposedly different fields;
  • implausibly rapid sampling;
  • missing photos;
  • unusually high sample collection rates;
  • duplicated Sample IDs.

Flags should prompt investigation rather than automatic rejection.

35. Daily Reconciliation

At the end of each field day:

[ \text{Physical samples held}

\text{completed sample records} ]

Any discrepancy should be investigated immediately.

Possible causes include:

  • missing sample;
  • duplicate record;
  • duplicate barcode;
  • damaged envelope;
  • data entry error;
  • sample placed in wrong batch.

IMAGE Nigeria reported improvements in Wave 2 from stronger sample traceability, daily coordination, dashboard monitoring and closer field-laboratory communication.

36. Sample Acceptance

A sample should normally be accepted where:

  • identity is clear;
  • Sample ID links to the correct record;
  • quantity is sufficient;
  • sample type is known;
  • packaging is intact;
  • tissue is sufficiently dry or can be dried further;
  • no major mould or rot is present;
  • contributing-plant requirements were met.
37. Conditional Acceptance

A sample may be retained for corrective action where:

  • further drying is required;
  • packaging needs replacement;
  • minor metadata can be reconciled confidently;
  • desiccant has become exhausted;
  • a small physical issue does not compromise identity.

Identity should never be repaired by guessing.

Any correction should preserve an audit trail.

38. Sample Rejection

Potential rejection reasons include:

  • unresolvable Sample ID;
  • sample cannot be linked to a source record;
  • mould;
  • rot;
  • severe contamination;
  • insufficient tissue;
  • severely damaged packaging;
  • excessive moisture with deterioration;
  • wrong crop or tissue;
  • fewer contributing plants than the protocol requires;
  • known mixing with another sample.

The rejection reason should be recorded rather than simply deleting the sample.

39. Crop-Specific Considerations

39.1 Rice

Possible materials include:

  • leaf;
  • panicle/grain;
  • crop-cut grain;
  • stored grain;
  • mill grain.

Consider:

  • standing crop stage;
  • storage mixing;
  • pooled grain interpretation;
  • need to germinate individual grain for single-plant analysis.

39.2 Common bean and cowpea

Possible materials include:

  • leaf;
  • pods;
  • grain;
  • crop-cut grain.

For expected pure-line materials, individual plants can provide relatively clean genotypes.

39.3 Wheat

Possible materials include:

  • leaf;
  • grain;
  • crop-cut harvest.

Interpretation of heterozygous marker signals requires additional analytical caution because some markers may detect paralogs.

This issue is addressed more fully in the analytical guidance.

39.4 Cassava

Possible materials include:

  • leaf tissue;
  • root tissue.

IMAGE Nigeria demonstrated successful field sampling of single- and multiple-plant leaf material and root sampling at aggregation points.

Root tissue therefore provides a practical option where leaves are unavailable.

39.5 Heterogeneous populations

For crops or varieties where genetic heterogeneity is expected, sample enough plants to represent the population.

Do not interpret within-population diversity automatically as contamination.

40. Common Risks and Controls
Risk Control
Sample taken from wrong planting Verify Planting ID before collection
Convenient plants selected Use predefined spatial selection procedure
Single plant interpreted as whole planting Record sample representation explicitly
Pooled sample interpreted as genetically pure Treat assignment as population-level evidence
Risk Control
Heterogeneous target represented by one plant Use population sampling
Different plants contribute unequal tissue Standardise approximate contribution
Cutting tools contaminate samples Clean between samples
External label lost Use robust/dual labelling
Barcode does not match digital record Scan and verify in field
Wet tissue moulds Begin drying promptly
Silica becomes exhausted Monitor and replace
Bag damaged Replace or double-bag
Grain from several fields mixed Sample before mixing or flag uncertainty
Stored grain assigned to wrong variety Record source confidence and mixing
Phenotype-targeted samples treated as random Store sampling strategy
Samples retained too long in field Establish transport schedule
Physical and digital sample counts differ Daily reconciliation
GPS/photo collected but not reviewed Use paradata QA flags
Country pilot configuration becomes universal rule Label crop- and activity-specific numbers as examples
41. Lessons from IMAGE

41.1 Sample identity is as important as tissue quality

A high-quality genotype has limited monitoring value if it cannot be linked confidently to the correct survey, planting or source record.

41.2 Single- and multiple-plant sampling answer different questions

Single plants provide clearer individual genotypes.

Multiple-plant samples provide population-level information.

Neither should be adopted universally.

41.3 Mixture can be a real biological result

Greater ambiguity in pooled samples does not automatically mean poor sampling or laboratory failure.

It may reflect genuine mixture within the sampled population.

41.4 Single plants can also support laboratory QA

Unexpected mixture-like signals in samples that should represent one clean plant can help identify possible:

  • contamination;
  • sample switching;
  • unusual biological events.

41.5 Drying is a critical field operation

Poor preservation can destroy otherwise useful samples.

Silica activity and bag condition should therefore be monitored actively rather than simply placing envelopes in desiccant once.

41.6 Alternative tissue types expand monitoring options

Cassava root sampling demonstrated that monitoring does not always need to depend on leaf availability.

41.7 Aggregation points can be efficient sampling locations

Markets, processors and mills can provide efficient access to material from many growers but support a different inference from field sampling.

41.8 Practical training matters

Nigeria trained enumerators using both classroom instruction and simulated field sampling for leaf and root protocols before deployment.

41.9 Field and laboratory teams should remain connected during implementation

Nigeria Wave 2 identified real-time laboratory engagement, dedicated logistics and dashboard-based monitoring as useful practices for strengthening sample quality and traceability.

42. Context-Dependent Decisions

This guidance does not prescribe one universal:

  • number of single plants;
  • number of plants in a pooled sample;
  • walking pattern;
  • leaf quantity;
  • grain quantity;
  • root section size;
  • silica quantity;
  • number of envelopes per drying bag;
  • sample-transport frequency;
  • preferred tissue type;
  • aggregation-point design;
  • single- versus multiple-plant configuration.

These decisions should follow:

  • monitoring objective;
  • crop biology;
  • sample representation;
  • laboratory requirements;
  • field conditions;
  • available resources.
43. Related Guidance

This guidance should be used with:

Planning and Designing a Genotyped Crop Survey

Defines:

  • monitoring question;
  • sample representation;
  • target population;
  • single/multiple-plant rationale.

Integrating Genotyping into Existing Agricultural Surveys and Crop-Cut Systems

Provides specific guidance where plant material is collected within existing surveys.

Sample Traceability and Laboratory Workflow

Covers:

  • batch handover;
  • laboratory accession;
  • sample processing;
  • backup samples;
  • plate preparation;
  • genotyping shipment.

Developing and Maintaining a Genetic Reference Library

Provides additional guidance where the samples being collected are reference materials rather than farmer-field survey material.

Analysing and Reporting Genotyped Crop Survey Results

Addresses:

  • interpretation of pooled versus individual genotypes;
  • mixture diagnostics;
  • heterozygosity;
  • divergence;
  • classification.
44. Tools & Downloads

Sampling design

  • Plant-Sample Strategy Decision Tree
  • Single- versus Multiple-Plant Decision Guide
  • Crop-Specific Sampling Annex Template
  • Staged-Sampling Planning Sheet

Field implementation

  • Field Sampling Checklist
  • Plant-Selection Route Job Aid
  • Leaf-Sampling Job Aid
  • Grain-Sampling Job Aid
  • Cassava Root-Sampling Job Aid
  • Wet-Weather Sampling Job Aid

Identification and quality

  • Sample Metadata Template
  • Sample ID Verification Checklist
  • Daily Sample Reconciliation Sheet
  • Field QA and Paradata Checklist
  • Sample Acceptance and Rejection Checklist

Preservation and logistics

  • Silica-Gel Monitoring Sheet
  • Sample Storage Checklist
  • Batch Handover Form
  • Field-to-Laboratory Sample Manifest
45. Evidence and Adaptation

Overall evidence base: Strong operational evidence, with sample composition and crop-specific implementation remaining context-dependent.

Strongly supported through IMAGE experience

The evidence supports:

  • linking every physical sample permanently to the relevant survey/source record;
  • using healthy plant material suitable for DNA extraction;
  • cleaning tools between samples;
  • drying samples promptly;
  • monitoring desiccant activity;
  • maintaining sample identity during transport;
  • daily reconciliation of physical and digital records;
  • interpreting single- and multiple-plant samples according to different biological purposes;
  • using single-plant samples for clearer individual genotypes;
  • using multiple-plant samples for population-level representation;
  • considering target-material homogeneity when choosing sampling strategy;
  • use of leaf, grain and cassava root tissue under appropriate conditions;
  • aggregation-point sampling as a viable alternative monitoring pathway;
  • field QA through GPS, timestamps and photographs.

Evidence-based but context-dependent

The appropriate method depends on crop, objective and operating context for:

  • single- versus multiple-plant sampling;
  • combined sampling;
  • staged sampling;
  • random versus phenotype-targeted sampling;
  • standing crop versus stored grain;
  • field versus aggregation-point sampling;
  • leaf versus grain versus root;
  • number of contributing plants;
  • field-selection route;
  • tissue quantity;
  • preservation configuration.

Should not be treated as universal IMAGE standards

IMAGE does not establish one mandatory:

  • number of plants per pooled sample;
  • number of single plants per planting;
  • W-shaped, zig-zag or other route;
  • tissue quantity;
  • silica-gel quantity;
  • transport frequency;
  • sample container configuration;
  • crop-specific sampling age or stage.

Country and crop protocols used different configurations according to their objectives and operational circumstances.

The guiding principle is:

Define what the sample must represent, collect material in a way that preserves that representation, and protect its identity and biological quality until it reaches the laboratory.

Sample Traceability and Laboratory Workflow

Microsite Summary

A genotyped crop survey depends on maintaining an unbroken link between the physical plant sample, the survey or reference record from which it originated, the laboratory material prepared from it, and the genotype result eventually returned.

The sample journey should therefore be treated as one continuous chain:

Survey/GRL record → Sample ID → Field collection → Field batch → Handover → Laboratory receipt → Accession → Processing → Backup sample → Genotyping order → Shipment → Provider receipt → Genotype result → Link back to source record

A sample can be biologically excellent but have little monitoring value if its identity cannot be established confidently. IMAGE experience showed that identifier and sample-tracking problems can compromise or even prevent linkage of genotype results to socioeconomic, geographic and reference information.

Traceability should therefore be designed before fieldwork begins and maintained through every transfer, processing step and analytical handover.

The central principle is:

Every physical sample, processed aliquot and genotype result should remain traceable to one authoritative Sample ID and the original survey, planting, inventory or reference record from which it came.

1. Introduction and Purpose

This guidance supports institutions developing procedures for:

  • sample identification;
  • field-to-laboratory chain of custody;
  • batch management;
  • sample receipt and accession;
  • acceptance, conditional acceptance and rejection;
  • laboratory processing;
  • contamination prevention;
  • primary and backup sample preparation;
  • tube, rack and plate management;
  • preparation of genotyping orders;
  • shipment to a genotyping provider;
  • confirmation of provider receipt;
  • reconciliation of returned genotype data.

The guidance begins when identifiers and physical sample containers are prepared and continues until genotype results have been linked successfully back to the originating survey or Genetic Reference Library record.

It complements the preceding guidance on Selecting, Collecting and Preserving Plant Material.

It does not prescribe:

  • DNA extraction chemistry;
  • sequencing procedures;
  • marker-panel operation;
  • bioinformatic classification;
  • laboratory quality-management systems beyond the requirements needed to preserve sample identity and integrity.

Those functions should follow the laboratory and genotyping-provider methods in use.

2. Intended Users

This guidance is intended for:

  • survey data managers;
  • field coordinators;
  • enumerators and sampling technicians;
  • field supervisors;
  • transport and submission officers;
  • laboratory receiving officers;
  • laboratory technicians;
  • GRL managers;
  • genotyping coordinators;
  • quality-assurance staff;
  • data managers;
  • institutions shipping samples to external genotyping providers.

The full workflow should be designed jointly.

Traceability should not be treated as the responsibility of only the laboratory or only the field team.

3. Why Traceability Matters

Genotyped varietal monitoring combines several information systems:

  • household or survey data;
  • planting or field information;
  • physical plant material;
  • laboratory records;
  • genotyping orders;
  • genotype files;
  • GRL information;
  • analytical results.

The Sample ID is the connection among these systems.

If that connection fails, it may become impossible to determine:

  • where a sample came from;
  • which field or planting it represents;
  • what sample type was collected;
  • whether it was single- or multiple-plant material;
  • which laboratory preparation produced a genotype;
  • which genotype belongs to a household;
  • whether the sample is a survey sample or a reference sample.

IMAGE close-out work documented situations where genotypes could not be used confidently because the physical material could not be reconciled reliably with the associated records.

Traceability is therefore a scientific quality requirement, not simply an administrative convenience.

4. Design the Identifier System Before Fieldwork

Minimum requirement

The identifier structure should be defined before sample containers are prepared or field teams are deployed.

At minimum, the system should distinguish:

  • Study or Survey ID;
  • Household/Source ID;
  • Planting, Field, Inventory or Lot ID;
  • Sample ID;
  • Batch ID;
  • laboratory accession or processing identifier where used;
  • genotyping order;
  • plate/rack position where relevant.

The identifier hierarchy should preserve the relationship:

Study → Source → Sampling unit → Physical sample

For survey samples, this may be:

Survey → Household → Crop → Planting → Sample

For GRL material:

GRL study → Variety → Source → Inventory → Sample

5. Use One Authoritative Sample ID

Minimum requirement

Each physical biological sample should have one unique, permanent Sample ID.

That ID should remain associated with the sample through:

  • collection;
  • preservation;
  • transport;
  • laboratory receipt;
  • processing;
  • backup preparation;
  • genotyping submission;
  • genotype output.

Do not change the core identifier merely because the sample enters another institution.

Where laboratories need internal accession numbers, retain a mapping:

Original Sample ID ↔ Laboratory Accession ID

rather than replacing the original identifier.

6. Characteristics of a Good Sample ID

A Sample ID should be:

  • unique;
  • permanent;
  • readable;
  • sufficiently short for practical field and laboratory use;
  • compatible with digital survey systems;
  • compatible with laboratory systems;
  • resistant to transcription errors;
  • usable in spreadsheets and genotype files without truncation or reformatting.

Avoid identifiers that depend only on:

  • respondent names;
  • farmer-reported variety names;
  • spreadsheet row numbers;
  • filenames;
  • position in an unversioned list.

These can change or be duplicated.

7. Encode Information Carefully

A Sample ID may contain useful structure, for example:

IMAGE-NG-CAS-0048-SP01

where components could represent:

  • project;
  • country;
  • crop;
  • unique sample number;
  • sample type.

However, avoid embedding so much information into the identifier that:

  • IDs become excessively long;
  • field teams mistype them;
  • crop or sample classifications later need to change;
  • the same identifier is interpreted differently by different systems.

The authoritative information should remain in the metadata record rather than relying entirely on interpretation of the ID string.

8. Use Machine-Readable and Human-Readable Labels

Recommended practice

Use both:

  • a barcode or other machine-readable identifier; and
  • a visible human-readable Sample ID.

The machine-readable label reduces manual transcription.

The human-readable identifier provides:

  • visual confirmation;
  • a fallback if the barcode cannot be scanned;
  • support during physical reconciliation.

IMAGE operational materials repeatedly used barcode-based sample tracking.

9. Use Duplicate Labels Where Appropriate

Where envelopes or containers allow it, duplicate identification may be useful.

For example:

  • one external label;
  • one duplicate internal identifier.

This reduces the risk that the sample becomes unidentifiable if the external label:

  • detaches;
  • becomes wet;
  • fades;
  • is damaged during transport.

The field and laboratory procedure should define how duplicate labels are used without creating duplicate samples accidentally.

10. Validate Identifiers Electronically

Where digital survey or laboratory systems are used, configure checks for:

  • duplicate IDs;
  • missing IDs;
  • invalid formats;
  • barcode reuse;
  • mismatched sample type;
  • Sample ID linked to more than one planting;
  • impossible crop/sample combinations.

The system should prevent or flag errors as early as possible.

Correcting one duplicate Sample ID in the field is much easier than reconstructing its identity after genotyping.

11. Link the Sample to Its Source at Collection

Minimum requirement

At the point of collection, the Sample ID should be linked to the correct:

  • survey or study;
  • household/source;
  • crop;
  • planting/field/inventory/lot;
  • farmer- or source-reported variety where relevant;
  • sample type;
  • collection date;
  • collector.

For pooled samples, also record:

  • number of contributing plants;
  • sampling strategy.

For single-plant samples, record the individual sample designation where required.

The basic relationship should remain:

Source record → Sample ID

rather than attempting to reconstruct the source from the genotype file later.

12. Scan and Visually Verify

Recommended practice

Where barcodes are used:

1. scan the barcode;

2. confirm the Sample ID displayed digitally;

3. compare it visually with the physical label;

4. confirm the correct planting or source record;

5. collect the material;

6. close and protect the container.

Scanning alone should not replace visual confirmation because the wrong valid barcode can still be scanned.

13. Track Sample Status Through the Entire Workflow

A useful status sequence is:

1. Identifier assigned

2. Collected

3. Field QC complete

4. Submitted by field team

5. Received at laboratory

6. Accepted

7. Conditionally accepted

8. Rejected

9. Processing started

10. Processed

11. Backup retained

12. Added to genotyping order

13. Shipped

14. Received by provider

15. Genotyping complete

16. Result received

17. Result linked to source data

18. Archived

IMAGE guidance developed this type of end-to-end status model to make it possible to determine where each sample is at any point in the workflow.

Each status should ideally include:

  • date;
  • responsible person;
  • location;
  • remarks where relevant.
14. Organise Samples Into Field Batches

Recommended practice

Samples should move from field teams to receiving facilities in identifiable batches.

Each batch should have a unique Batch ID.

A batch may be organised by:

  • field team;
  • geographic area;
  • crop;
  • collection period;
  • receiving laboratory;
  • another operational unit.

The Batch ID does not replace Sample IDs.

It provides a practical container for managing many individual samples.

15. Prepare a Field Batch Manifest

Every batch should be accompanied by a manifest.

Minimum fields may include:

Field Purpose
Batch ID Identifies the shipment/transfer
Sample ID Identifies each sample
Crop Confirms material
Tissue Leaf, grain, root, etc.
Sample type Single, pooled, etc.
Enumerator/sampler Accountability
Condition Preliminary QC
Remarks Deviations or issues

The manifest should be generated from the digital sample records wherever possible rather than recreated manually.

16. Reconcile Samples Before Field Handover

Before submitting a batch, the field supervisor should confirm:

  • every physical sample appears on the manifest;
  • every manifest entry has a physical sample;
  • identifiers are readable;
  • no duplicate Sample IDs exist;
  • samples are sufficiently preserved;
  • damaged packages are identified;
  • protocol deviations are recorded.

The core reconciliation is:

Physical samples submitted = valid manifest records

Any discrepancy should be resolved before the batch moves where possible.

17. Record Every Handover

Minimum requirement

Each transfer of custody should be documented.

Examples include:

  • enumerator → supervisor;
  • supervisor → transport officer;
  • transport officer → receiving laboratory;
  • laboratory → courier;
  • courier → genotyping provider.

A handover record should identify:

  • Batch ID;
  • submitting officer;
  • receiving officer;
  • date and time;
  • number expected;
  • number submitted;
  • discrepancies;
  • condition;
  • confirmation of receipt.

IMAGE operational guidance strongly supports explicit handover documentation.

18. Protect Samples During Transport

Transport procedures should maintain:

  • sample identity;
  • packaging integrity;
  • appropriate environmental conditions;
  • separation of batches;
  • security.

Samples should not be transported:

  • loose;
  • without manifests;
  • with unreadable labels;
  • in containers likely to become wet;
  • in conditions incompatible with their preservation method.

The transport officer should not alter sample identifiers.

19. Receive and Reconcile Samples at the Laboratory

Minimum requirement

Laboratory receipt should begin with reconciliation before processing.

The receiving officer should:

1. confirm Batch ID;

2. count physical samples;

3. compare the count with the manifest;

4. confirm individual Sample IDs;

5. inspect sample condition;

6. record discrepancies;

7. assign acceptance status;

8. record storage location.

Do not start grinding, subsampling or plate preparation before major identity discrepancies have been resolved.

20. Use a Laboratory Accession Log

The accession record may contain:

Sample IDBatch IDDate receivedConditionDecisionStorage locationProcessing statusRemarks

Where the laboratory uses its own accession number, include both:

  • original Sample ID;
  • laboratory accession number.

The mapping should remain permanent.

21. Classify Samples at Receipt

Samples can be categorised as:

Accepted

The sample is:

  • identifiable;
  • linked to a valid record;
  • of suitable condition;
  • sufficient in quantity;
  • appropriate for processing.

Conditionally accepted

The sample may require:

  • additional drying;
  • relabelling supported by clear evidence;
  • packaging replacement;
  • metadata reconciliation.

Rejected

The sample cannot be used reliably.

Possible reasons include:

  • mould;
  • rot;
  • severe moisture damage;
  • insufficient material;
  • missing label;
  • unresolvable identifier mismatch;
  • missing source record;
  • severe contamination;
  • wrong crop;
  • wrong material;
  • damaged packaging that compromises identity.

IMAGE laboratory guidance recommends identifying poor-quality or untraceable material before investing further processing effort.

22. Do Not Repair Identity by Guessing

Minimum requirement

If a label does not match the record, do not infer the sample identity from:

  • position in the box;
  • crop appearance;
  • neighbouring sample numbers;
  • expected sequence;
  • memory.

Investigate using evidence such as:

  • field records;
  • barcode logs;
  • photographs;
  • batch manifests;
  • collector notes.

Where identity cannot be established confidently, reject or quarantine the sample.

23. Maintain an Audit Trail for Corrections

Where a discrepancy can be resolved legitimately, record:

  • original information;
  • corrected information;
  • reason;
  • supporting evidence;
  • person approving the correction;
  • date.

Do not silently overwrite incorrect Sample IDs or metadata.

The audit trail should allow a later reviewer to reconstruct what changed.

24. Provide Feedback to Field Teams

Sample-quality problems should not remain solely within the laboratory.

Feedback should identify patterns such as:

  • wet samples;
  • mould;
  • damaged envelopes;
  • missing labels;
  • duplicate IDs;
  • insufficient tissue;
  • incorrect sample type;
  • incomplete manifests.

Rapid feedback allows field teams to correct procedures while sampling is still underway.

IMAGE country experience showed that stronger field--laboratory communication and traceability improved later implementation.

25. Stabilise Samples Before Processing

After receipt, accepted samples should be maintained under conditions suitable for the material type.

This may include:

  • continued silica drying;
  • additional drying;
  • cool dry storage;
  • another laboratory-approved stabilisation approach.

Laboratory teams should confirm that material is ready before:

  • grinding;
  • cutting;
  • transferring;
  • sealing into processing tubes.

Processing incompletely dried material can increase quality and contamination risks.

26. Process Only One Identifiable Sample at a Time

Recommended practice

Laboratory benches should be organised to minimise sample switching.

A technician should verify:

1. source Sample ID;

2. destination tube/container;

3. sample type;

4. processing step;

before material is transferred.

Where practical:

  • keep only the current sample open;
  • close processed containers before opening the next;
  • organise samples according to the working manifest.
27. Prevent Cross-Contamination During Processing

Minimum requirement

Equipment that contacts biological material should be cleaned between samples.

Depending on the tissue and equipment, this may include:

  • scissors;
  • scalpels;
  • grinders;
  • grinding chambers;
  • forceps;
  • work surfaces.

IMAGE protocols repeatedly used approximately 70--75% ethanol for appropriate cutting tools, while grinding procedures included cleaning between samples.

The laboratory SOP should specify the appropriate cleaning procedure for its equipment.

28. Process Grain Carefully

Where grain is prepared for genotyping, the laboratory may need to:

  • confirm adequate dryness;
  • grind the grain;
  • transfer an appropriate quantity to a tube;
  • retain backup material.

The exact grinding and tissue quantity should follow the genotyping provider's specifications.

The general requirement is:

the processed material must remain linked unambiguously to the original Sample ID.

Grinders should be cleaned sufficiently between samples to avoid carry-over.

29. Process Leaf and Other Tissue Carefully

For dried leaf or other tissue:

  • verify the Sample ID before opening;
  • take the provider-required amount;
  • transfer it to the correct destination tube;
  • retain original material where required;
  • record the transfer.

Where tissue must be cut or subsampled:

  • use clean equipment;
  • avoid transferring fragments from neighbouring samples;
  • close the source envelope after use.
30. Prepare Primary and Backup Samples Deliberately

Recommended practice

Where sufficient material is available, prepare:

  • a primary sample for genotyping;
  • a retained backup.

IMAGE laboratory guidance recommends preparing primary and backup material rather than exhausting the entire sample in one submission.

A backup can support:

  • repeat genotyping;
  • investigation of failed samples;
  • resolution of unexpected analytical results;
  • replacement of lost or damaged shipments.
31. Label Backup Material Clearly

Backup tubes should not create ambiguity with the primary sample.

One approach is to retain the core Sample ID and append a controlled suffix, for example:

  • SAMPLE123-A
  • SAMPLE123-B

or another institutionally defined convention.

The metadata should identify:

  • which is the primary;
  • which is the backup;
  • storage location;
  • date prepared. Do not create an unrelated new Sample ID that breaks the relationship to the original sample.
32. Define Backup Retention Policy

Context-dependent

Institutions should decide:

  • which samples require backups;
  • minimum retained quantity;
  • storage conditions;
  • storage location;
  • retention duration;
  • conditions for disposal;
  • who can authorise use of the backup.

IMAGE does not establish one universal storage duration.

The policy should reflect:

  • sample value;
  • cost of recollection;
  • expected need for repeat analysis;
  • storage capacity;
  • national institutional requirements.
33. Manage Tubes, Racks and Plates as Traceability Objects

Where samples are transferred into:

  • tubes;
  • racks;
  • 96-well plates;
  • other multi-position formats,

the position becomes part of the chain of custody.

Each transfer should preserve:

Sample ID → Container ID → Position

For example:

IMAGE-018462 → Plate P07 → Well C06

The plate map should be stored electronically and checked before shipment.

34. Do Not Rely on Physical Position Alone

Minimum requirement

A sample must not be identified solely because it is:

"the third tube in row two."

If tubes shift during handling, positional identity can be lost.

Where possible, individual tubes should also carry:

  • Sample ID;
  • barcode or other machine-readable identifier.

The plate map provides an additional relationship rather than replacing the Sample ID.

35. Verify Every Source-to-Destination Transfer

At each transfer, confirm:

  • source Sample ID;
  • destination ID;
  • rack/plate;
  • well position.

This is a critical quality-control point because a sample switch introduced during plate preparation can generate a technically valid genotype assigned to the wrong field or reference. IMAGE guidance identifies transfer to tubes or plates as a formal QC checkpoint.

36. Use Controls According to the Laboratory/Provider Method

Where a genotyping platform requires:

  • blanks;
  • reference controls;
  • replicates;
  • control varieties,

their placement should be preserved in the plate map and order documentation.

The number and type of controls should follow the analytical method and provider requirements.

This guidance does not prescribe one universal control configuration.

37. Prepare the Genotyping Order From the Accessioned Sample List

Minimum requirement

The provider order file should be generated from the samples actually prepared for shipment.

Do not prepare the definitive order file only from the original field list because some samples may have been:

  • rejected;
  • conditionally accepted;
  • lost;
  • replaced;
  • not processed.

The final order should correspond exactly to the physical shipment.

38. Minimum Genotyping Order Information

Provider-specific requirements vary, but the order may include:

  • Sample ID;
  • crop/species;
  • tissue type;
  • plate or rack;
  • well position;
  • requested service;
  • project/order reference.

Only information required by the provider should be shared.

The provider generally does not need access to confidential household survey data.

39. Reconcile the Order File, Plate Map and Physical Samples

Minimum requirement

Before shipment, confirm:

Order records = physical shipment samples = plate/rack map

Check for:

  • missing samples;
  • extra samples;
  • duplicate IDs;
  • wrong plate positions;
  • incorrect crop;
  • samples marked rejected but included;
  • backup samples accidentally included as primary samples.

Shipment should not proceed until discrepancies are resolved.

40. Prepare a Shipment Manifest

A shipment manifest may include:

Provider orderPlate/Rack IDWell/PositionSample IDCropTissueBackup retainedRemarks

The shipment package should contain the documentation required by:

  • the laboratory;
  • the courier;
  • the provider;
  • applicable national authorities.
41. Comply With Shipment and Permit Requirements

Context-dependent

Cross-border shipment of biological materials may require:

  • permits;
  • phytosanitary documentation;
  • material-transfer documentation;
  • customs declarations;
  • provider import instructions.

These requirements vary by:

  • country;
  • crop;
  • tissue type;
  • destination;
  • provider.

The project should confirm requirements before the intended shipment date.

IMAGE materials do not establish one universal export or import procedure.

42. Record Shipment Tracking

Record:

  • shipment date;
  • courier;
  • tracking number;
  • sender;
  • destination;
  • provider order;
  • number of plates/racks or samples;
  • expected delivery.

Tracking should be linked to the shipment record rather than maintained only in personal email.

43. Confirm Provider Receipt

Minimum requirement

The chain of custody does not end when samples leave the local laboratory.

Confirm:

  • package received;
  • number of plates/packages received;
  • physical condition;
  • provider order recognised;
  • any missing or damaged material;
  • provider acceptance.

IMAGE traceability guidance explicitly includes confirmation of provider receipt as part of the sample chain.

44. Record Provider Feedback

Provider feedback may include:

  • insufficient tissue;
  • poor DNA quality;
  • failed processing;
  • wrong species;
  • sample contamination;
  • unreadable identifiers;
  • failed genotyping.

These outcomes should be linked back to the Sample ID.

Do not remove failed samples silently from the dataset.

Their status may matter for:

  • non-response analysis;
  • field/laboratory QA;
  • repeat submission;
  • sample-success reporting.
45. Reconcile Returned Genotype Files

Minimum requirement

When genotype results are returned:

1. identify all returned Sample IDs;

2. compare them with the submitted order;

3. identify missing results;

4. identify unexpected IDs;

5. identify duplicates;

6. record failed samples;

7. confirm that Sample IDs join correctly to the source metadata. The chain is complete only when the genotype result can be linked confidently to its original sample record.

IMAGE guidance treats result reconciliation as the final chain-of-custody checkpoint.

46. Preserve Raw Provider Identifiers

Where the provider modifies, prefixes or otherwise formats IDs, retain:

  • original submitted Sample ID;
  • provider-returned ID;
  • explicit mapping between them.

Do not permanently replace the project identifier with the provider's internal representation.

47. Maintain a Sample-Status Tracker

Recommended practice

A central tracker should make it possible to answer:

  • Was the sample collected?
  • Where is it?
  • Was it accepted?
  • Was it processed?
  • Is a backup available?
  • Was it shipped?
  • Did the provider receive it?
  • Did genotyping succeed?
  • Has the result been linked to the survey or GRL dataset?

IMAGE traceability guidance proposes this type of status tracking as a core operational tool.

48. Separate Physical Status From Analytical Classification

Do not use the same field to describe:

Physical workflow status

Examples:

  • received;
  • accepted;
  • rejected;
  • shipped;
  • genotype failed.

and:

Analytical classification

Examples:

  • Matched-Unique;
  • Group;
  • Genetic Entity;
  • Unidentified.

These describe different processes and should remain separate in the data model.

49. Roles and Responsibilities

Survey data manager

Responsible for:

  • identifier structure;
  • barcode validation;
  • duplicate prevention;
  • survey-to-sample linkage;
  • audit trails.

Enumerator or sampler

Responsible for:

  • verifying identifiers;
  • correct labelling;
  • recording sample type;
  • protecting material;
  • reporting deviations.

Field supervisor

Responsible for:

  • daily reconciliation;
  • manifests;
  • field discrepancy resolution;
  • batch preparation.

Transport/submission officer

Responsible for:

  • secure transport;
  • signed handovers;
  • delivery to laboratory.

Receiving laboratory officer

Responsible for:

  • receipt;
  • count reconciliation;
  • condition assessment;
  • acceptance/rejection;
  • storage assignment.

Sample-processing officer

Responsible for:

  • processing;
  • contamination prevention;
  • backup preparation;
  • tube/rack/plate mapping.

Genotyping coordinator

Responsible for:

  • provider orders;
  • shipment documentation;
  • delivery confirmation;
  • provider feedback;
  • reconciliation of returned results.

These functions may be combined in smaller programmes, but responsibilities should remain explicit.

50. Quality-Control Checkpoints

The workflow should include formal checkpoints.

Checkpoint 1 -- Identifier assignment

Confirm:

  • uniqueness;
  • correct format;
  • readable barcode;
  • correct label.

Checkpoint 2 -- Field collection

Confirm:

  • correct sample/source linkage;
  • barcode scanned;
  • sample type recorded;
  • container protected.

Checkpoint 3 -- Daily field reconciliation

Confirm:

  • physical samples equal digital records;
  • no duplicates;
  • no unlabelled samples;
  • preservation acceptable.

Checkpoint 4 -- Laboratory receipt

Confirm:

  • count;
  • manifest;
  • identity;
  • condition;
  • acceptance status.

Checkpoint 5 -- Processing transfer

Confirm:

  • source Sample ID;
  • destination tube;
  • plate/rack position;
  • tools cleaned.

Checkpoint 6 -- Pre-shipment

Confirm:

  • physical samples match order file;
  • plate map complete;
  • shipment documents ready;
  • backups recorded.

Checkpoint 7 -- Result receipt

Confirm:

  • returned IDs reconcile;
  • failed samples identified;
  • genotype data join successfully to source metadata.

These checkpoints reflect the workflow developed from IMAGE sample-handling experience.

51. Common Risks and Controls
Risk Control
Duplicate Sample IDs Electronic uniqueness validation
Barcode attached to wrong sample Scan and visual verification at collection
Sample and digital record disagree Resolve before field handover
Samples go missing between field and lab Batch manifest and signed handover
Laboratory accepts untraceable sample Quarantine/reject unresolved IDs
Wet or mouldy samples processed unnecessarily Condition assessment at receipt
Sample identity guessed from physical sequence Require evidence-based reconciliation
Corrections overwrite original information Maintain audit trail
Samples switch during grinding or transfer One-sample-at-a-time workflow and destination verification
Cross-contamination during processing Clean equipment between samples
Risk Control
Backup and primary confused Controlled suffix and metadata
Tubes shift in rack Individual Sample ID + position map
Plate map differs from provider order Pre-shipment reconciliation
Rejected samples remain in order file Build order from accepted processed samples
Shipment arrives damaged Record tracking and provider receipt condition
Provider changes ID formatting Maintain submitted-to-returned ID crosswalk
Failed genotypes disappear from final dataset Retain failure status
Genotype cannot be linked to survey data Final returned-ID reconciliation
Multiple institutions maintain conflicting sample lists Establish one authoritative status tracker
52. Lessons from IMAGE

52.1 Traceability is a scientific requirement

A genotype without a reliable source link cannot support credible varietal-monitoring interpretation.

52.2 Errors should be detected as early as possible

Identifier problems identified:

  • in the field are easiest to resolve;
  • at laboratory receipt are harder;
  • after genotyping may be impossible to resolve confidently.

52.3 Physical and digital records should be reconciled repeatedly

Reconciliation should happen:

  • daily in the field;
  • at every handover;
  • at laboratory receipt;
  • before shipment;
  • when results return.

52.4 The chain continues beyond the local laboratory

Shipping samples successfully is not the endpoint.

Provider receipt and returned genotype reconciliation are part of the same chain.

52.5 Backup material reduces operational risk

Where sufficient sample material exists, retaining a backup provides an option when:

  • shipment is lost;
  • genotyping fails;
  • results require confirmation.

52.6 Laboratory processing can introduce identity errors

A perfectly tracked field sample can still be compromised by:

  • tube switching;
  • plate-map errors;
  • contamination;
  • incorrect order files.

Traceability must therefore continue through processing.

52.7 Rapid field--laboratory feedback improves implementation

IMAGE country experience showed that stronger traceability and closer coordination reduced reconciliation effort and supported faster resolution of problems.

52.8 Returned genotype data require a final custody check

Successful technical genotyping does not by itself confirm that the result is linked correctly.

The returned Sample ID must reconcile with the original source data.

53. Context-Dependent Decisions

This guidance does not prescribe one universal:

  • Sample ID format;
  • barcode technology;
  • barcode standard;
  • Batch ID structure;
  • frequency of field-to-lab transfer;
  • laboratory accession numbering system;
  • backup quantity;
  • backup-storage period;
  • processing-tube format;
  • rack or plate configuration;
  • electronic versus paper handover signature;
  • courier;
  • shipment permit process;
  • provider-order format.

These should be adapted to:

  • survey software;
  • field connectivity;
  • laboratory information systems;
  • crop and tissue type;
  • sample volume;
  • genotyping provider;
  • institutional data systems;
  • national regulations.

The underlying traceability principles should remain constant even where the technology differs.

54. Minimum Records to Retain

At the completion of the workflow, the project should retain at least:

1. Sample-ID specification

2. Survey/sample linkage dataset

3. Field sample records

4. Batch manifests

5. Handover records

6. Laboratory accession log

7. Acceptance/rejection records

8. Correction and discrepancy log

9. Processing records

10. Backup-sample register

11. Rack/plate maps

12. Genotyping order files

13. Shipment manifests

14. Courier/tracking records

15. Provider receipt confirmation

16. Provider sample-quality feedback

17. Returned genotype files

18. Submitted-to-returned ID mapping where needed

19. Final sample-status tracker

These records collectively provide the audit trail from field collection to analytical data.

55. Related Guidance

This guidance should be used with:

Planning and Designing a Genotyped Crop Survey

Defines the survey identifier hierarchy and intended survey-to-sample linkage.

Selecting, Collecting and Preserving Plant Material

Covers:

  • physical sampling;
  • sample type;
  • preservation;
  • field QA;
  • initial labelling.

Integrating Genotyping into Existing Agricultural Surveys and Crop-Cut Systems

Explains how Sample IDs should coexist with existing national survey identifiers.

Developing and Maintaining a Genetic Reference Library

Applies the same traceability principles to reference materials and inventories.

GRL Metadata and Tracking Standard

Defines the persistent metadata relationships for reference varieties, sources, inventories and genotype profiles.

Analysing and Reporting Genotyped Crop Survey Results

Uses the final reconciled Sample IDs to link genotype classifications back to survey and reference data.

56. Tools & Downloads

Identification

  • Sample-ID Specification Template
  • Barcode Preparation Checklist
  • Sample/Survey Linkage Template

Field logistics

  • Field Batch Manifest
  • Daily Sample Reconciliation Sheet
  • Field Handover Form
  • Sample-Status Tracker

Laboratory receipt

  • Sample Receipt Form
  • Laboratory Accession Log
  • Acceptance/Rejection Checklist
  • Discrepancy and Corrective-Action Form

Processing

  • Sample Processing Log
  • Primary/Backup Sample Register
  • Tube/Rack Mapping Template
  • Plate Map Template

Shipment

  • Genotyping Order Checklist
  • Shipment Manifest
  • Pre-Shipment Reconciliation Checklist
  • Provider Receipt Confirmation Record

Final reconciliation

  • Returned Genotype Reconciliation Template
  • Sample Failure Tracker
  • Final Chain-of-Custody Audit Checklist

The IMAGE consolidation work identified these as the core templates needed to operationalise the traceability and laboratory workflow.

57. Evidence and Adaptation

Overall evidence base: Strong operational evidence from IMAGE field, laboratory and genotyping workflows.

Strongly supported through IMAGE experience

The available evidence supports:

  • unique permanent Sample IDs;
  • machine-readable and human-readable identifiers;
  • physical-to-digital sample linkage;
  • batch manifests;
  • repeated physical/digital reconciliation;
  • documented handovers;
  • laboratory accessioning;
  • explicit acceptance and rejection;
  • contamination prevention during processing;
  • preparation of backup samples where practical;
  • tube/rack/plate position tracking;
  • reconciliation of physical shipment with provider order files;
  • shipment tracking;
  • confirmation of provider receipt;
  • reconciliation of returned genotype IDs with original source records.

Evidence-based but institution-dependent

Institutions should determine:

  • exact identifier syntax;
  • barcode technology;
  • accession system;
  • transfer frequency;
  • backup-retention policy;
  • plate organisation;
  • laboratory software;
  • electronic versus paper signatures;
  • sample-storage duration.

Should not be treated as universal IMAGE standards

IMAGE does not establish one mandatory:

  • barcode format;
  • Sample ID prefix;
  • shipment frequency;
  • laboratory accession platform;
  • number of backup aliquots;
  • backup-storage duration;
  • plate layout;
  • courier;
  • permit process;
  • provider-order format.

The guiding principle is:

At every stage, an independent reviewer should be able to determine what the sample is, where it came from, what happened to it, where it is now, and which genotype result was generated from it.